VACON DRIVES PRODUCTS LIST

Please send your inquiry to our export sales: info@alandcontrols.com

Vacon NX_ OPTIONS External RFI-filters   * CONDUCTED EMISSIONS, MOTOR CABLE MAX. 5  M : C-LEVEL
ORDER TYPE CODE SUITABILITY DESCRIPTION DIMENSIONS W x H x D [mm]
RFI-0012-5-5 FR4,MF4 / 380-500V C-LEVEL, IP54, footprint 125x390x65
RFI-0031-5-5 FR5,MF5 / 380-500V C-LEVEL, IP54, footprint 135x490x65
RFI-0061-5-5 FR6,MF6 / 380-500V C-LEVEL, IP54, footprint 185x620x75
      Transfer products
ORDER TYPE CODE SUITABILITY DIMENSIONS
500V:   W x H x D [mm]
RFI-0150-5-0                NXS, NXP                                                                                                                                                                                300x120x160
RFI-0130-5-0                NXS, NXP                                                                                                                                                                                439x240x110
RFI-0250-5-0                NXS, NXP                                                                                                                                                                                300x125x180
RFI-0320-5-0                NXS, NXP                                                                                                                                                                                300x115x210
RFI-0400-5-0                NXS, NXP                                                                                                                                                                                300x115x210
RFI-0600-5-0                NXS, NXP                                                                                                                                                                                300x135x210
RFI-1000-5-0                NXS, NXP                                                                                                                                                                                350x170x230
RFI-1600-5-0                NXS, NXP                                                                                                                                                                                400x160x250
RFI-2500-5-0                NXS, NXP                                                                                                                                                                                600x200x300
RFI-0042-6-0                NXS, NXP                                                                                                                                                                                 329x185x70
RFI-0100-6-0                NXS, NXP                                                                                                                                                                                 379x220x90
RFI-0180-6-0                NXS, NXP                                                                                                                                                                                300x120x160
RFI-0300-6-0                NXS, NXP                                                                                                                                                                                300x115x210
RFI-0400-6-0                NXS, NXP                                                                                                                                                                                300x115x210
RFI-0600-6-0                NXS, NXP                                                                                                                                                                                300x135x210
RFI-0900-6-0                NXS, NXP                                                                                                                                                                                350x170x230
NX_00035    C              NX_**                                     * Factory option
NX_00045    C              NX_**                                     * Factory option
NX_00055    C              NX_**                                     * Factory option
NX_00075    C              NX_**                                     * Factory option
NX_00095    C              NX_**                                     * Factory option
NX_00125    C              NX_**                                     * Factory option
NX_00165    C              NX_**                                     * Factory option
NX_00225    C              NX_**                                     * Factory option
NX_00315    C              NX_**                                     * Factory option
NX_00385    C              NX_**                                     * Factory option
NX_00455    C              NX_**                                     * Factory option
NX_00615    C              NX_**                                     * Factory option
IP5-FR4 FR4,MF4 IP54 kit
IP5-FR5 FR5,MF5 IP54 kit
IP5-FR6 FR6,MF6 IP54 kit
THR-FR4                       FR4, MF4                                 Flange mounting kit for IP21 to the back
THR-FR5                       FR5, MF5                                 Flange mounting kit for IP21 to the back
THR-FR6                       FR6, MF6                                 Flange mounting kit for IP21 to the back
THR-FR7                       FR7                                         Flange mounting kit for IP21 to the back
THR-FR8                       FR8                                         Flange mounting kit for IP21 to the back
THR-FR9                       FR9                                         Flange mounting kit for IP21 to the back
THR-FR4-54 FR4, MF4 Flange mounting kit for IP54 to the back
THR-FR5-54 FR5, MF5 Flange mounting kit for IP54 to the back
THR-FR6-54 FR6, MF6 Flange mounting kit for IP54 to the back
PAN-A                          NXS,NXP                                  Alphanumeric display panel
PAN-B                          NX_                                         No display panel, reduction price
PAN-C                          NXL                                         7-segment display panel
PAN-RS                        NXL                                         RS232C adapter panel
PAN-G                          NXS,NXP                                  Graphical display panel
PAN-F                          NXS,NXP                                  Dummy keypad (just case, LED's visible)
DRA-02B                      NXS,NXP                                  Door installation set for display panel, 2m cable
DRA-04B                      NXS,NXP                                  Door installation set for display panel, 4m cable
DRA-15B                      NXS,NXP                                  Door installation set for display panel, 15m cable
DRA-02L                      NXL                                         Door installation set for display panel, 2m cable
DRA-04L                      NXL                                         Door installation set for display panel, 4m cable
RS232C-2M                  NX_                                         2m RS232 serial link cable, pin to pin
RS232C-4M                  NX_                                         4m RS232 serial link cable, pin to pin
RS232C-15M                NX_                                         15m RS232 serial link cable, pin to pin
RS232-1,5M                 NXS, NXP                                1,5M RS232 PC-cable
SYS-1M                        NXP                                         Fiber optic cable (pair), 1m
SYS-2M                        NXP                                         Fiber optic cable (pair), 2m
SYS-4M                        NXP                                         Fiber optic cable (pair), 4m
SYS-10M                      NXP                                         Fiber optic cable (pair), 10m
OPT-A1                        NXS,NXP                                  6DI,1DO,2AI(mA/V),1AO(mA/V),+10Vref,+24V/EXT+24V
OPT-A2                        NXS,NXP                                  2RO(NO/NC)
OPT-A3                        NXS,NXP                                  1RO(NO/NC),1RO(NC), 1 Thermistor
OPT-A4                        NXP (NXS)                               3DI(Encoder RS422),Out +5V/+15V
OPT-A5                        NXP (NXS)                               3DI(Encoder 10...24V),Out +15V/+24V
OPT-A7                        NXP                                         Double encoder (Wide Range), 6D1, 2xDO
OPT-A8                        NXS, NXP                                 As NXOPTA1, but analog I/O and +10Vref galv. de-coupled as a group
OPT-A9                        NXS, NXP                                 As NXOPTA1, but 2,5mm² terminals
OPT-AA                        NXL                                         3DI,1RO(NO/NC),1DO
OPT-AE                        NXP (NXS)                               Encoder board (Wide Range), 3DI(Encoder 10...24V),Out +15V/+24V,2DO (encoder divider and direction)
OPT-AI                         NXL                                         I/O expander board for NXL, 3DI, 1RO (NO), Therm
OPT-B1                        NXS, NXP, (NXL)                      6DI/DO (programmable, DI or DO)
OPT-B2                        NX_                                         1RO(NO/NC),1RO(NO),Therm
OPT-B4                        NX_                                         1AI(mA, isolated),2AO(mA, isolated),+24V/EXT+24V
OPT-B5                        NX_                                         3RO(NO)
OPT-B8                        NXS, NXP (NXL)                       3Pt100,+24V/EXT+24V
OPT-B9                        NXS, NXP (NXL)                       1RO(NO), 5 pcs of 41...240VAC input
OPT-BB                        NXP                                         ENDAT encoder card, 2xDO (RS422)
OPT-BC                        NXP                                         RESOLVER, 3x DO (Wide Range)
OPT-C2                        NX_                                         RS485 (Modbus/N2)
OPT-C3                        NX_                                         Profibus DP
OPT-C4                        NX_                                         LonWorks
OPT-C5                        NX_                                         Profibus DP (D9 type connector)
OPT-C6                        NX_                                         CANopen (slave)
OPT-C7                        NX_                                         DeviceNet
OPT-C8                        NX_                                         RS485 (D9 type connector, Modbus/RS485)
OPT-CI                         NX_                                         MODBUS / TCP check the availability from the factory
OPT-CJ                         NX_                                         BACnet
OPT-CF                        NXS, NXP                                 Can/Euromap
OPT-CG                        NXS, NXP                                 SELMA 2 PROTOCOL (SAMI)
OPT-D1                        NXP                                         System Bus adapter (2xfiber optic pairs)
OPT-D2                        NXP                                         System Bus(1xfiber optic pair) & CAN-bus (galv. decoupled)
OPT-D3                        NXS, NXP                                 RS232 adapter card (not galvanically decoupled)
OPT-D6                        NXP                                         CAN-Bus (galv. decoupled)
OPT-A1r   1)                 NXS,NXP                                  6DI, 1DO, 2AI(mA/V), 1AO(mA/V),+10Vref,+24V/EXT+24V
OPT-A2r  1)                  NXS,NXP                                  2RO(NO/NC)
1)   REDUCTION PRICE, (THIS CARD IS A STANDARD IN NXS/NXP PRODUCTS)  
Vacon NC1131-3 Engineering tool (Personal Licence)                                                                                   *
Vacon NC1131-3 Engineering tool (Company Site Licence)                                                                           *
Vacon NC1131-3 Engineering tool (Annual Maintenance fee)                                                                        *
NCDrive and NCLoad                                                                                                                                  1 cd including both NCDrive and NCLoad
ASFIFF12 NXS, NXP High Speed Application (>1900Hz)
APFIFF11 NXP Shaft Synchronization Application
APFIFF12 NXP Position Control Application
NXS Demo                    NXS                                         115-230V demo case, motor included
NXP Demo                    NXP                                         115-230V demo case, motor included
NXL Demo 1                 NXL                                         115V demo, switches and pots included, no motor
NXL Demo 2                 NXL                                         230V demo, switches and pots included, no motor
NXL                     V       NXL MF4-6                               Varnished PCB's, includes all circuit boards in the unit
NX                       V       NXS&NXP FR4-8, CH3-CH5       Varnished PCB's, includes all circuit boards in the unit
NX                       G      FR9-FR13, CH3-CH5                 Varnished PCB's, includes all circuit boards in the unit
NX                       B       FR9-FR13 IP00                         Varnished PCB´s for FR10-FR13 IP00 modules
DIN-MF2                      NXL MF2                                  Din-rail assembly option
DIN-MF3                      NXL MF3                                  Din-rail assembly option
NXC02615A2H0SSFA1A2 110 205 308 132 261 FR9/IP21 606x2275x605 308
NXC02615A5H0SSFA1A2 110 205 308 132 261 FR9/IP54 606x2405x605 318
+ACH                                          Cabinet heater 50W                              1 x 50W*
+ACL                                           Cabinet light                                        *
+AMO                                         ICB motor operator                              including Open/Close push buttons on the door *
+CIT                                           Cabling Input Top                                 Including COT (W:+400mm)
+DCM                                          Analog meter + curr.trafo                     CT on L1
+DVM                                          Analog V-meter + sel.sw.                      For main voltages
+GPL                                           100mm base/plinth                              For basic drive ***
+ICB                                           Circuit breaker                                     MCCB, not with ILS, IFU or IFD
+ICO                                           Contactor AC-1                                    *
+IFD                                           Fuse Switch + aR fuses                         Not with ILS, IFU or ICB
+IFU                                           aR fuses & base                                   Not with ILS, ICB or IFD
+ILS                                           Load Switch                                         Not with IFU, ICB or IFD
+MDC                                          Terminals for DC connect.                     DC-connection / additional dc/brake chopper terminals
+OCM                                         Common mode chokes                          To be put on motor cable
+ODU                                          du/dt-filter                                          Including CIT/COT (W:+400mm) **
NXC03005A2H0SSFA1A2 132 245 368 160 300 FR9/IP21 606x2275x605 308
NXC03005A5H0SSFA1A2 132 245 368 160 300 FR9/IP54 606x2405x605 318
+ACH                                          Cabinet heater 50W                              1 x 50W*
+ACL                                           Cabinet light                                        *
+AMO                                         ICB motor operator                              including Open/Close push buttons on the door *
+CIT                                           Cabling Input Top                                 Including COT (W:+400mm)
+DCM                                          Analog meter + curr.trafo                     CT on L1
+DVM                                          Analog V-meter + sel.sw.                      For main voltages
+GPL                                           100mm base/plinth                              For basic drive ***
+ICB                                           Circuit breaker                                     MCCB, not with ILS, IFU or IFD
+ICO                                           Contactor AC-1                                    *
+IFD                                           Fuse Switch + aR fuses                         Not with ILS, IFU or ICB
+IFU                                           aR fuses & base                                   Not with ILS, ICB or IFD
+ILS                                           Load Switch                                         Not with IFU, ICB or IFD
+MDC                                          Terminals for DC connect.                     DC-connection / additional dc/brake chopper terminals
+OCM                                         Common mode chokes                          To be put on motor cable
+ODU                                          du/dt-filter                                          Including CIT/COT (W:+400mm) **
NXC03855A2L0SSFA1A2 160 300 450 200 385 FR10/IP21 606x2275x605 371
NXC03855A5L0SSFA1A2 160 300 450 200 385 FR10/IP54 606x2405x605 381
+ACH                                          Cabinet heater 50W                              1 x 50W*
+ACL                                           Cabinet light                                        *
+AMO                                         ICB motor operator                              including Open/Close push buttons on the door *
+CIT                                           Cabling Input Top                                 Including COT (W:+400mm)
+DCM                                          Analog meter + curr.trafo                     CT on L1
+DVM                                          Analog V-meter + sel.sw.                      For main voltages
+GPL                                           100mm base/plinth                              For basic drive ***
+ICB                                           Circuit breaker                                     MCCB, not with ILS, IFU or IFD
+ICO                                           Contactor AC-1                                    *
+IFD                                           Fuse Switch + aR fuses                         Not with ILS, IFU or ICB
+IFU                                           aR fuses & base                                   Not with ILS, ICB or IFD
+ILS                                           Load Switch                                         Not with IFU, ICB or IFD
+MDC                                          Terminals for DC connect.                     DC-connection / additional dc/brake chopper terminals
+OCM                                         Common mode chokes                          To be put on motor cable
+ODU                                          du/dt-filter                                          Including CIT/COT (W:+400mm) **
NXC04605A2L0SSFA1A2 200 385 578 250 460 FR10/IP21 606x2275x605 403
NXC04605A5L0SSFA1A2 200 385 578 250 460 FR10/IP54 606x2405x605 413
+ACH                                          Cabinet heater 50W                              1 x 50W*
+ACL                                           Cabinet light                                        *
+AMO                                         ICB motor operator                              including Open/Close push buttons on the door *
+CIT                                           Cabling Input Top                                 Including COT (W:+400mm)
+DCM                                          Analog meter + curr.trafo                     CT on L1
+DVM                                          Analog V-meter + sel.sw.                      For main voltages
+GPL                                           100mm base/plinth                              For basic drive ***
+ICB                                           Circuit breaker                                     MCCB, not with ILS, IFU or IFD
+ICO                                           Contactor AC-1                                    *
+IFD                                           Fuse Switch + aR fuses                         Not with ILS, IFU or ICB
+IFU                                           aR fuses & base                                   Not with ILS, ICB or IFD
+ILS                                           Load Switch                                         Not with IFU, ICB or IFD
+MDC                                          Terminals for DC connect.                     DC-connection / additional dc/brake chopper terminals
+OCM                                         Common mode chokes                          To be put on motor cable
+ODU                                          du/dt-filter                                          Including CIT/COT (W:+400mm) **
NXC05205A2L0SSFA1A2 250 460 690 250 520 FR10/IP21 606x2275x605 403
NXC05205A5L0SSFA1A2 250 460 690 250 520 FR10/IP54 606x2405x605 413
+ACH                                          Cabinet heater 50W                              1 x 50W*
+ACL                                           Cabinet light                                        *
+AMO                                         ICB motor operator                              including Open/Close push buttons on the door *
+CIT                                           Cabling Input Top                                 Including COT (W:+400mm)
+DCM                                          Analog meter + curr.trafo                     CT on L1
+DVM                                          Analog V-meter + sel.sw.                      For main voltages
+GPL                                           100mm base/plinth                              For basic drive ***
+ICB                                           Circuit breaker                                     MCCB, not with ILS, IFU or IFD
+ICO                                           Contactor AC-1                                    *
+IFD                                           Fuse Switch + aR fuses                         Not with ILS, IFU or ICB
+IFU                                           aR fuses & base                                   Not with ILS, ICB or IFD
+ILS                                           Load Switch                                         Not with IFU, ICB or IFD
+MDC                                          Terminals for DC connect.                     DC-connection / additional dc/brake chopper terminals
+OCM                                         Common mode chokes                          To be put on motor cable
+ODU                                          du/dt-filter                                          Including CIT/COT (W:+400mm) **
NXC05905A2L0SSFA1A2 250 520 780 315 590 FR11/IP21 806x2275x605 577
NXC05905A5L0SSFA1A2 250 520 780 315 590 FR11/IP54 806x2405x605 590
+ACH                                          Cabinet heater 50W                              1 x 50W*
+ACL                                           Cabinet light                                        *
+AMO                                         ICB motor operator                              including Open/Close push buttons on the door *
+CIT                                           Cabling Input Top                                 Including COT (W:+400mm)
+DCM                                          Analog meter + curr.trafo                     CT on L1
+DVM                                          Analog V-meter + sel.sw.                      For main voltages
+GPL                                           100mm base/plinth                              For basic drive ***
+ICB                                           Circuit breaker                                     MCCB, not with ILS, IFU or IFD *
+ICO                                           Contactor AC-1                                    *
+IFD                                           Fuse Switch + aR fuses                         Not with ILS, IFU or ICB
+IFU                                           aR fuses & base                                   Not with ILS, ICB or IFD
+ILS                                           Load Switch                                         Not with IFU, ICB or IFD
+MDC                                          Terminals for DC connect.                     DC-connection / additional dc/brake chopper terminals
+OCM                                         Common mode chokes                          To be put on motor cable
+ODU                                          du/dt-filter                                          Including CIT/COT (W:+400mm) **
NXC06505A2L0SSFA1A2 315 590 885 355 650 FR11/IP21 806x2275x605 577
NXC06505A5L0SSFA1A2 315 590 885 355 650 FR11/IP54 806x2405x605 590
+ACH                                          Cabinet heater 50W                              1 x 50W*
+ACL                                           Cabinet light                                        *
+AMO                                         ICB motor operator                              including Open/Close push buttons on the door *
+CIT                                           Cabling Input Top                                 Including COT (W:+400mm)
+DCM                                          Analog meter + curr.trafo                     CT on L1
+DVM                                          Analog V-meter + sel.sw.                      For main voltages
+GPL                                           100mm base/plinth                              For basic drive ***
+ICB                                           Circuit breaker                                     MCCB, not with ILS, IFU or IFD *
+ICO                                           Contactor AC-1                                    *
+IFD                                           Fuse Switch + aR fuses                         Not with ILS, IFU or ICB
+IFU                                           aR fuses & base                                   Not with ILS, ICB or IFD
+ILS                                           Load Switch                                         Not with IFU, ICB or IFD
+MDC                                          Terminals for DC connect.                     DC-connection / additional dc/brake chopper terminals
+OCM                                         Common mode chokes                          To be put on motor cable
+ODU                                          du/dt-filter                                          Including CIT/COT (W:+400mm) **
NXC07305A2L0SSFA1A2 355 650 975 400 730 FR11/IP21 806x2275x605 577
NXC07305A5L0SSFA1A2 355 650 975 400 730 FR11/IP54 806x2445x605 590
+ACH                                          Cabinet heater 50W                              1 x 50W*
+ACL                                           Cabinet light                                        *
+AMO                                         ICB motor operator                              including Open/Close push buttons on the door *
+CIT                                           Cabling Input Top                                 Including CIT/COT (W:+400mm) **
+DCM                                          Analog meter + curr.trafo                     CT on L1
+DVM                                          Analog V-meter + sel.sw.                      For main voltages
+GPL                                           100mm base/plinth                              For basic drive ***
+ICB                                           Circuit breaker                                     MCCB, not with ILS, IFU or IFD *
+ICO                                           Contactor AC-1                                    *
+IFD                                           Fuse Switch + aR fuses                         Not with ILS, IFU or ICB
+IFU                                           aR fuses & base                                   Not with ILS, ICB or IFD
+ILS                                           Load Switch                                         Not with IFU, ICB or IFD
+MDC                                          Terminals for DC connect.                     DC-connection / additional dc/brake chopper terminals
+OCM                                         Common mode chokes                          To be put on motor cable
+ODU                                          du/dt-filter                                          Including CIT/COT (W:+400mm) **
NXC08205A2L0SSFA1A2 400 730 1095 450 820 FR12/IP21    1206x2275x605 810
NXC08205A5L0SSFA1A2 400 730 1095 450 820 FR12/IP54    1206x2405x605 830
+ACH                                          Cabinet heater 50W                              2 x 50W*
+ACL                                           Cabinet light                                        *
+CIT                                           Cabling Input Top                                 Including COT (W:+400mm)
+DCM                                          Analog meter + curr.trafo                     CT on L1
+DVM                                          Analog V-meter + sel.sw.                      For main voltages
+GPL                                           100mm base/plinth                              For basic drive ***
+ICB                                           Circuit breaker, including +AMO            MCCB, not with ILS, IFU or IFD *
+ICO                                           Contactor AC-1                                    *
+IFD                                           Fuse Switch + aR fuses                         Not with ILS, IFU or ICB
+IFU                                           aR fuses & base                                   Not with ILS, ICB or IFD
+ILS                                           Load Switch                                         Not with IFU, ICB or IFD
+MDC                                          Terminals for resistor connect.              Brake chopper terminals
+OCM                                         Common mode chokes                          To be put on motor cable
+ODU                                          du/dt-filter                                          Including CIT/COT (W:+400mm) **
NXC09205A2L0SSFA1A2 450 820 1230 500 920 FR12/IP21    1206x2275x605 810
NXC09205A5L0SSFA1A2 450 820 1230 500 920 FR12/IP54    1206x2405x605 830
+ACH                                          Cabinet heater 50W                              2 x 50W*
+ACL                                           Cabinet light                                        *
+CIT                                           Cabling Input Top                                 Including COT (W:+400mm)
+DCM                                          Analog meter + curr.trafo                     CT on L1
+DVM                                          Analog V-meter + sel.sw.                      For main voltages
+GPL                                           100mm base/plinth                              For basic drive ***
+ICB                                           Circuit breaker, including +AMO            MCCB, not with ILS, IFU or IFD *
+ICO                                           Contactor AC-1                                    *
+IFD                                           Fuse Switch + aR fuses                         Not with ILS, IFU or ICB
+IFU                                           aR fuses & base                                   Not with ILS, ICB or IFD
+ILS                                           Load Switch                                         Not with IFU, ICB or IFD
+MDC                                          Terminals for resistor connect.              Brake chopper terminals
+OCM                                         Common mode chokes                          To be put on motor cable
+ODU                                          du/dt-filter                                          Including CIT/COT (W:+400mm) **
NXC10305A2L0SSFA1A2 500 920 1380 560 1030 FR12/IP21    1206x2275x605 810
NXC10305A5L0SSFA1A2 500 920 1380 560 1030 FR12/IP54    1206x2405x605 830
+ACH                                          Cabinet heater 50W                              2 x 50W*
+ACL                                           Cabinet light                                        *
+CIT                                           Cabling Input Top                                 Including COT (W:+400mm)
+DCM                                          Analog meter + curr.trafo                     CT on L1
+DVM                                          Analog V-meter + sel.sw.                      For main voltages
+GPL                                           100mm base/plinth                              For basic drive ***
+ICB                                           Circuit breaker, including +AMO            MCCB, not with ILS, IFU or IFD *
+ICO                                           Contactor AC-1                                    *
+IFD                                           Fuse Switch + aR fuses                         Not with ILS, IFU or ICB
+IFU                                           aR fuses & base                                   Not with ILS, ICB or IFD
+ILS                                           Load Switch                                         Not with IFU, ICB or IFD
+MDC                                          Terminals for resistor connect.              Brake chopper terminals
+OCM                                         Common mode chokes                          To be put on motor cable
+ODU                                          du/dt-filter                                          Including CIT/COT (W:+400mm) **
NXC11505A2L0SSFA1A2 +IFD 560 1030 1545 630 1150 FR13/IP21    1406x2275x605 1050
NXC11505A5L0SSFA1A2 +IFD 560 1030 1545 630 1150 FR13/IP54    1406x2405x605 1060
+ACH                                          Cabinet heater 50W                              2 x 50W*
+ACL                                           Cabinet light                                        *
+CIT                                           Cabling Input Top                                 Including COT (W:+400mm)
+DCM                                          Analog meter + curr.trafo                     CT on L1
+DVM                                          Analog V-meter + sel.sw.                      For main voltages
+GPL                                           100mm base/plinth                              For basic drive **
+ICB                                           Circuit breaker, including +AMO            MCCB, not with +IFD, this option upgrades +IFD to +ICB *
+MDC                                          Terminals for DC connect.                     Including COT (W:+400mm)
+OCM                                         Common mode chokes                          To be put on motor cable
+ODU                                          du/dt-filter
NXC13005A2L0SSFA1A2 +IFD 630 1150 1725 710 1300 FR13/IP21    1606x2275x605 1250
NXC13005A5L0SSFA1A2 +IFD 630 1150 1725 710 1300 FR13/IP54    1606x2405x605 1260
+ACH                                          Cabinet heater 50W                              2 x 50W*
+ACL                                           Cabinet light                                        *
+CIT                                           Cabling Input Top                                 Including COT (W:+400mm)
+DCM                                          Analog meter + curr.trafo                     CT on L1
+DVM                                          Analog V-meter + sel.sw.                      For main voltages
+GPL                                           100mm base/plinth                              For basic drive **
+ICB                                           Circuit breaker, including +AMO            MCCB, not with +IFD, this option upgrades +IFD to +ICB *
+MDC                                          Terminals for DC connect.                     Including COT (W:+400mm)
+OCM                                         Common mode chokes                          To be put on motor cable
+ODU                                          du/dt-filter
NXC14505A2L0SSFA1A2 +IFD 710 1300 1950 800 1450 FR13/IP21    1606x2275x605 1250
NXC14505A5L0SSFA1A2 +IFD 710 1300 1950 800 1450 FR13/IP54    1606x2405x605 1260
+ACH                                          Cabinet heater 50W                              2 x 50W*
+ACL                                           Cabinet light                                        *
+CIT                                           Cabling Input Top                                 Including COT (W:+400mm)
+DCM                                          Analog meter + curr.trafo                     CT on L1
+DVM                                          Analog V-meter + sel.sw.                      For main voltages
+GPL                                           100mm base/plinth                              For basic drive **
+ICB                                           Circuit breaker, including +AMO            MCCB, not with +IFD, this option upgrades +IFD to +ICB *
+MDC                                          Terminals for DC connect.                     Including COT (W:+400mm)
+OCM                                         Common mode chokes                          To be put on motor cable
+ODU                                          du/dt-filter
NXC17705A2L0SSFA1A2 +ICB 900 1600 2400 1000 1770 FR14/IP21    2806x2275x605 2250
NXC17705A5L0SSFA1A2 +ICB 900 1600 2400 1000 1770 FR14/IP54    2806x2405x605 2280
+ACH                                          Cabinet heater 50W                              2 x 50W*
+ACL                                           Cabinet light                                        *
+CIT                                           Cabling Input Top                                 Including COT (W:+400mm)
+DCM                                          Analog meter + curr.trafo                     CT on L1
+DVM                                          Analog V-meter + sel.sw.                      For main voltages
+GPL                                           100mm base/plinth                              For each G40/G60/G80, (H:+100mm)
+OCM                                         Common mode chokes                          To be put on motor cable
+ODU                                          dUdt-filter                                           Including COT (W:+400mm)
NXC21505A2L0SSFA1A2 +ICB 1100 1940 2910 1200 2150 FR14/IP21    2806x2275x605 2300
NXC21505A5L0SSFA1A2 +ICB 1100 1940 2910 1200 2150 FR14/IP54    2806x2405x605 2330
+ACH                                          Cabinet heater 50W                              2 x 50W*
+ACL                                           Cabinet light                                        *
+CIT                                           Cabling Input Top                                 Including COT (W:+400mm)
+DCM                                          Analog meter + curr.trafo                     CT on L1
+DVM                                          Analog V-meter + sel.sw.                      For main voltages
+GPL                                           100mm base/plinth                              For each G40/G60/G80, (H:+100mm)
+OCM                                         Common mode chokes                          To be put on motor cable
+ODU                                          dUdt-filter                                           Including COT (W:+400mm)
NXC03855A2L0TSFA1A2 160 300 450 200 385 FR10/IP21 606x2275x605 371
NXC03855A5L0TSFA1A2 160 300 450 200 385 FR10/IP54 606x2405x605 381
+ACH                                                             Cabinet heater 50W                               1 x 50W*
+ACL                                                              Cabinet light                                         *
+AMO                                                             ICB motor operator                                including Open/Close push buttons on the door *
+CIT                                                              Cabling Input Top                                  Including COT (W:+400mm)
+DCM                                                             Analog meter + curr.trafo                      CT on L1
+DVM                                                             Analog V-meter + sel.sw.                       For main voltages
+GPL                                                              100mm base/plinth                                For basic drive ***
+ICB                                                              Circuit breaker                                      MCCB, not with IFU *
+IFU                                                              aR fuses & base                                     Not with ICB
+OCM                                                            Common mode chokes                           To be put on motor cable
+ODU                                                             du/dt-filter                                            Including CIT/COT (W:+400mm) **
NXC04605A2L0TSFA1A2 200 385 578 250 460 FR10/IP21 606x2275x605 403
NXC04605A5L0TSFA1A2 200 385 578 250 460 FR10/IP54 606x2405x605 413
+ACH                                                             Cabinet heater 50W                               1 x 50W*
+ACL                                                              Cabinet light                                         *
+AMO                                                             ICB motor operator                                including Open/Close push buttons on the door *
+CIT                                                              Cabling Input Top                                  Including COT (W:+400mm)
+DCM                                                             Analog meter + curr.trafo                      CT on L1
+DVM                                                             Analog V-meter + sel.sw.                       For main voltages
+GPL                                                              100mm base/plinth                                For basic drive ***
+ICB                                                              Circuit breaker                                      MCCB, not with IFU *
+IFU                                                              aR fuses & base                                     Not with ICB
+OCM                                                            Common mode chokes                           To be put on motor cable
+ODU                                                             du/dt-filter                                            Including CIT/COT (W:+400mm) **
NXC05205A2L0TSFA1A2 250 460 690 250 520 FR10/IP21 606x2275x605 403
NXC05205A5L0TSFA1A2 250 460 690 250 520 FR10/IP54 606x2405x605 413
+ACH                                                             Cabinet heater 50W                               1 x 50W*
+AMO                                                             ICB motor operator                                including Open/Close push buttons on the door *
+ACL                                                              Cabinet light                                         *
+CIT                                                              Cabling Input Top                                  Including COT (W:+400mm)
+DCM                                                             Analog meter + curr.trafo                      CT on L1
+DVM                                                             Analog V-meter + sel.sw.                       For main voltages
+GPL                                                              100mm base/plinth                                For basic drive ***
+ICB                                                              Circuit breaker                                      MCCB, not with IFU *
+IFU                                                              aR fuses & base                                     Not with ICB
+OCM                                                            Common mode chokes                           To be put on motor cable
+ODU                                                             du/dt-filter                                            Including CIT/COT (W:+400mm) **
NXC05905A2L0TSFA1A2 250 520 780 315 590 FR11/IP21 806x2275x605 577
NXC05905A5L0TSFA1A2 250 520 780 315 590 FR11/IP54 806x2405x605 590
+ACH                                                             Cabinet heater 50W                               1 x 50W*
+ACL                                                              Cabinet light                                         *
+AMO                                                             ICB motor operator                                including Open/Close push buttons on the door *
+CIT                                                              Cabling Input Top                                  Including COT (W:+400mm)
+DCM                                                             Analog meter + curr.trafo                      CT on L1
+DVM                                                             Analog V-meter + sel.sw.                       For main voltages
+GPL                                                              100mm base/plinth                                For basic drive ***
+ICB                                                              Circuit breaker                                      MCCB, not with ILS, IFU or IFD *
+ICO                                                              Contactor AC-1                                      *
+IFD                                                              Fuse Switch + aR fuses                          Not with ILS, IFU or ICB
+IFU                                                              aR fuses & base                                     Not with ILS, ICB or IFD
+ILS                                                              Load Switch                                          Not with IFU, ICB or IFD
+OCM                                                            Common mode chokes                           To be put on motor cable
+ODU                                                             du/dt-filter                                            Including CIT/COT (W:+400mm) **
NXC06505A2L0TSFA1A2 315 590 885 355 650 FR11/IP21 806x2275x605 577
NXC06505A5L0TSFA1A2 315 590 885 355 650 FR11/IP54 806x2405x605 590
+ACH                                                             Cabinet heater 50W                               1 x 50W*
+ACL                                                              Cabinet light                                         *
+AMO                                                             ICB motor operator                                including Open/Close push buttons on the door *
+CIT                                                              Cabling Input Top                                  Including COT (W:+400mm)
+DCM                                                             Analog meter + curr.trafo                      CT on L1
+DVM                                                             Analog V-meter + sel.sw.                       For main voltages
+GPL                                                              100mm base/plinth                                For basic drive ***
+ICB                                                              Circuit breaker                                      MCCB, not with ILS, IFU or IFD *
+ICO                                                              Contactor AC-1                                      *
+IFD                                                              Fuse Switch + aR fuses                          Not with ILS, IFU or ICB
+IFU                                                              aR fuses & base                                     Not with ILS, ICB or IFD
+ILS                                                              Load Switch                                          Not with IFU, ICB or IFD
+OCM                                                            Common mode chokes                           To be put on motor cable
+ODU                                                             du/dt-filter                                            Including CIT/COT (W:+400mm) **
NXC07305A2L0TSFA1A2 355 650 975 400 730 FR11/IP21 806x2275x605 577
NXC07305A5L0TSFA1A2 355 650 975 400 730 FR11/IP54 806x2445x605 590
+ACH                                                             Cabinet heater 50W                               1 x 50W*
+ACL                                                              Cabinet light                                         *
+AMO                                                             ICB motor operator                                including Open/Close push buttons on the door *
+CIT                                                              Cabling Input Top                                  Including COT (W:+400mm)
+DCM                                                             Analog meter + curr.trafo                      CT on L1
+DVM                                                             Analog V-meter + sel.sw.                       For main voltages
+GPL                                                              100mm base/plinth                                For basic drive ***
+ICB                                                              Circuit breaker                                      MCCB, not with ILS, IFU or IFD *
+ICO                                                              Contactor AC-1                                      *
+IFD                                                              Fuse Switch + aR fuses                          Not with ILS, IFU or ICB
+IFU                                                              aR fuses & base                                     Not with ILS, ICB or IFD
+ILS                                                              Load Switch                                          Not with IFU, ICB or IFD
+OCM                                                            Common mode chokes                           To be put on motor cable
+ODU                                                             du/dt-filter                                            Including CIT/COT (W:+400mm) **
NXC08205A2L0TSFA1A2 400 730 1095 450 820 FR12/IP21 1206x2275x605 810
NXC08205A5L0TSFA1A2 400 730 1095 450 820 FR12/IP54 1206x2405x605 830
+ACH                                                             Cabinet heater 50W                               1 x 50W*
+ACL                                                              Cabinet light                                         *
+CIT                                                              Cabling Input Top                                  Including COT (W:+400mm)
+DCM                                                             Analog meter + curr.trafo                      CT on L1
+DVM                                                             Analog V-meter + sel.sw.                       For main voltages
+GPL                                                              100mm base/plinth                                For basic drive ***
+ICB                                                              Circuit breaker, including +AMO              MCCB, not with ILS, IFU or IFD *
+ICO                                                              Contactor AC-1                                      *
+IFD                                                              Fuse Switch + aR fuses                          Not with ILS, IFU or ICB
+IFU                                                              aR fuses & base                                     Not with ILS, ICB or IFD
+ILS                                                              Load Switch                                          Not with IFU, ICB or IFD
+OCM                                                            Common mode chokes                           To be put on motor cable
+ODU                                                             du/dt-filter                                            Including CIT/COT (W:+400mm) **
NXC09205A2L0TSFA1A2 450 820 1230 500 920 FR12/IP21 1206x2275x605 810
NXC09205A5L0TSFA1A2 450 820 1230 500 920 FR12/IP54 1206x2405x605 830
+ACH                                                             Cabinet heater 50W                               1 x 50W*
+ACL                                                              Cabinet light                                         *
+CIT                                                              Cabling Input Top                                  Including COT (W:+400mm)
+DCM                                                             Analog meter + curr.trafo                      CT on L1
+DVM                                                             Analog V-meter + sel.sw.                       For main voltages
+GPL                                                              100mm base/plinth                                For basic drive ***
+ICB                                                              Circuit breaker, including +AMO              MCCB, not with ILS, IFU or IFD *
+ICO                                                              Contactor AC-1                                      *
+IFD                                                              Fuse Switch + aR fuses                          Not with ILS, IFU or ICB
+IFU                                                              aR fuses & base                                     Not with ILS, ICB or IFD
+ILS                                                              Load Switch                                          Not with IFU, ICB or IFD
+OCM                                                            Common mode chokes                           To be put on motor cable
+ODU                                                             du/dt-filter                                            Including CIT/COT (W:+400mm) **
NXC10305A2L0TSFA1A2 500 920 1380 560 1030 FR12/IP21 1206x2275x605 810
NXC10305A5L0TSFA1A2 500 920 1380 560 1030 FR12/IP54 1206x2405x605 830
+ACH                                                             Cabinet heater 50W                               1 x 50W*
+ACL                                                              Cabinet light                                         *
+CIT                                                              Cabling Input Top                                  Including COT (W:+400mm)
+DCM                                                             Analog meter + curr.trafo                      CT on L1
+DVM                                                             Analog V-meter + sel.sw.                       For main voltages
+GPL                                                              100mm base/plinth                                For basic drive ***
+ICB                                                              Circuit breaker, including +AMO              MCCB, not with ILS, IFU or IFD *
+ICO                                                              Contactor AC-1                                      *
+IFD                                                              Fuse Switch + aR fuses                          Not with ILS, IFU or ICB
+IFU                                                              aR fuses & base                                     Not with ILS, ICB or IFD
+ILS                                                              Load Switch                                          Not with IFU, ICB or IFD
+OCM                                                            Common mode chokes                           To be put on motor cable
+ODU                                                             du/dt-filter                                            Including CIT/COT (W:+400mm) **
NXC11505A2L0TSFA1A2 +ICB +AMO 560 1030 1545 630 1150 FR13/IP21 1406x2275x605 1050
NXC11505A5L0TSFA1A2 +ICB +AMO 560 1030 1545 630 1150 FR13/IP54 1406x2405x605 1060
+ACH                                                             Cabinet heater 50W                               1 x 50W*
+ACL                                                              Cabinet light                                         *
+CIT                                                              Cabling Input Top                                  Including COT (W:+400mm)
+DCM                                                             Analog meter + curr.trafo                      CT on L1
+DVM                                                             Analog V-meter + sel.sw.                       For main voltages
+GPL                                                              100mm base/plinth                                For basic drive **
+OCM                                                            Common mode chokes                           To be put on motor cable
+ODU                                                             du/dt-filter
NXC13005A2N0TSFA1A2 +ICB +AMO 630 1150 1725 710 1300 FR13/IP21 2006x2275x605 1700
NXC13005A5N0TSFA1A2 +ICB +AMO 630 1150 1725 710 1300 FR13/IP54 2006x2405x605 1710
+ACH                                                             Cabinet heater 50W                               1 x 50W*
+ACL                                                              Cabinet light                                         *
+CIT                                                              Cabling Input Top                                  Including COT (W:+400mm)
+DCM                                                             Analog meter + curr.trafo                      CT on L1
+DVM                                                             Analog V-meter + sel.sw.                       For main voltages
+GPL                                                              100mm base/plinth                                For basic drive **
+OCM                                                            Common mode chokes                           To be put on motor cable
+ODU                                                             du/dt-filter
NXC14505A2N0TSFA1A2 +ICB +AMO 710 1300 1950 800 1450 FR13/IP21 2006x2275x605 1700
NXC14505A5N0TSFA1A2 +ICB +AMO 710 1300 1950 800 1450 FR13/IP54 2006x2405x605 1710
+ACH                                                             Cabinet heater 50W                               1 x 50W*
+ACL                                                              Cabinet light                                         *
+CIT                                                              Cabling Input Top                                  Including COT (W:+400mm)
+DCM                                                             Analog meter + curr.trafo                      CT on L1
+DVM                                                             Analog V-meter + sel.sw.                       For main voltages
+GPL                                                              100mm base/plinth                                For basic drive **
+OCM                                                            Common mode chokes                           To be put on motor cable
+ODU                                                             du/dt-filter
NXC17705A2L0TSFA1A2 +ICB +AMO 900 1600 2400 1000 1770 FR14/IP21 2806x2275x605 2250
NXC17705A5L0TSFA1A2 +ICB +AMO 900 1600 2400 1000 1770 FR14/IP54 2806x2405x605 2280
+ACH                                                             Cabinet heater 50W                               2 x 50W*
+ACL                                                              Cabinet light                                         *
+CIT                                                              Cabling Input Top                                  Including COT (W:+400mm)
+DCM                                                             Analog meter + curr.trafo                      CT on L1
+DVM                                                             Analog V-meter + sel.sw.                       For main voltages
+GPL                                                              100mm base/plinth                                For each G40/G60/G80, (H:+100mm)
+OCM                                                            Common mode chokes                           To be put on motor cable
+ODU                                                             dUdt-filter                                             Including COT (W:+400mm)
NXC21505A2L0TSFA1A2 +ICB +AMO 1100 1940 2910 1200 2150 FR14/IP21 2806x2275x605 2300
NXC21505A5L0TSFA1A2 +ICB +AMO 1100 1940 2910 1200 2150 FR14/IP54 2806x2405x605 2330
+ACH                                                             Cabinet heater 50W                               2 x 50W*
+ACL                                                              Cabinet light                                         *
+CIT                                                              Cabling Input Top                                  Including COT (W:+400mm)
+DCM                                                             Analog meter + curr.trafo                      CT on L1
+DVM                                                             Analog V-meter + sel.sw.                       For main voltages
+GPL                                                              100mm base/plinth                                For each G40/G60/G80, (H:+100mm)
+OCM                                                            Common mode chokes                           To be put on motor cable
+ODU                                                             dUdt-filter                                             Including COT (W:+400mm)
NXC01256A2L0SSFA1A2 90 100 150 110 125 FR9/IP21 606x2275x605 308
NXC01256A5L0SSFA1A2 90 100 150 110 125 FR9/IP54 606x2405x605 318
+ACH                                             Cabinet heater 50W                         1 x 50W*
+ACL                                             Cabinet light                                   *
+AMO                                            ICB motor operator                         including Open/Close push buttons on the door *
+CIT                                              Cabling Input Top                            Including COT (W:+400mm)
+DCM                                            Analog meter + curr.trafo                CT on L1
+DVM                                            Analog V-meter + sel.sw.                 For main voltages
+GPL                                             100mm base/plinth                         For basic drive ***
+ICB                                              Circuit breaker                                MCCB, not with ILS, IFU or IFD
+ICO                                              Contactor AC-1                               *
+IFD                                              Fuse Switch + aR fuses                    Not with ILS, IFU or ICB
+IFU                                              aR fuses & base                              Not with ILS, ICB or IFD
+ILS                                              Load Switch                                    Not with IFU, ICB or IFD
+MDC                                            Terminals for DC connect.                DC-connection / additional dc/brake chopper terminals
+OCM                                            Common mode chokes                     To be put on motor cable
+ODU                                            du/dt-filter                                     Including CIT/COT (W:+400mm) **
NXC01446A2L0SSFA1A2 110     125 188 132 144 FR9/IP21 606x2275x605 308
NXC01446A5L0SSFA1A2 110     125 188 132 144 FR9/IP54 606x2405x605 318
+ACH                                             Cabinet heater 50W                         1 x 50W*
+ACL                                             Cabinet light                                   *
+AMO                                            ICB motor operator                         including Open/Close push buttons on the door *
+CIT                                              Cabling Input Top                            Including COT (W:+400mm)
+DCM                                            Analog meter + curr.trafo                CT on L1
+DVM                                            Analog V-meter + sel.sw.                 For main voltages
+GPL                                             100mm base/plinth                         For basic drive ***
+ICB                                              Circuit breaker                                MCCB, not with ILS, IFU or IFD
+ICO                                              Contactor AC-1                               *
+IFD                                              Fuse Switch + aR fuses                    Not with ILS, IFU or ICB
+IFU                                              aR fuses & base                              Not with ILS, ICB or IFD
+ILS                                              Load Switch                                    Not with IFU, ICB or IFD
+MDC                                            Terminals for DC connect.                DC-connection / additional dc/brake chopper terminals
+OCM                                            Common mode chokes                     To be put on motor cable
+ODU                                            du/dt-filter                                     Including CIT/COT (W:+400mm) **
NXC01706A2L0SSFA1A2 132     144 216 160 170 FR9/IP21 606x2275x605 308
NXC01706A5L0SSFA1A2 132     144 216 160 170 FR9/IP54 606x2405x605 318
+ACH                                             Cabinet heater 50W                         1 x 50W*
+ACL                                             Cabinet light                                   *
+AMO                                            ICB motor operator                         including Open/Close push buttons on the door *
+CIT                                              Cabling Input Top                            Including COT (W:+400mm)
+DCM                                            Analog meter + curr.trafo                CT on L1
+DVM                                            Analog V-meter + sel.sw.                 For main voltages
+GPL                                             100mm base/plinth                         For basic drive ***
+ICB                                              Circuit breaker                                MCCB, not with ILS, IFU or IFD
+ICO                                              Contactor AC-1                               *
+IFD                                              Fuse Switch + aR fuses                    Not with ILS, IFU or ICB
+IFU                                              aR fuses & base                              Not with ILS, ICB or IFD
+ILS                                              Load Switch                                    Not with IFU, ICB or IFD
+MDC                                            Terminals for DC connect.                DC-connection / additional dc/brake chopper terminals
+OCM                                            Common mode chokes                     To be put on motor cable
+ODU                                            du/dt-filter                                     Including CIT/COT (W:+400mm) **
NXC02086A2L0SSFA1A2 160     170 255 200 208 FR9/IP21 606x2275x605 308
NXC02086A5L0SSFA1A2 160     170 255 200 208 FR9/IP54 606x2405x605 318
+ACH                                             Cabinet heater 50W                         1 x 50W*
+ACL                                             Cabinet light                                   *
+AMO                                            ICB motor operator                         including Open/Close push buttons on the door *
+CIT                                              Cabling Input Top                            Including COT (W:+400mm)
+DCM                                            Analog meter + curr.trafo                CT on L1
+DVM                                            Analog V-meter + sel.sw.                 For main voltages
+GPL                                             100mm base/plinth                         For basic drive ***
+ICB                                              Circuit breaker                                MCCB, not with ILS, IFU or IFD
+ICO                                              Contactor AC-1                               *
+IFD                                              Fuse Switch + aR fuses                    Not with ILS, IFU or ICB
+IFU                                              aR fuses & base                              Not with ILS, ICB or IFD
+ILS                                              Load Switch                                    Not with IFU, ICB or IFD
+MDC                                            Terminals for DC connect.                DC-connection / additional dc/brake chopper terminals
+OCM                                            Common mode chokes                     To be put on motor cable
+ODU                                            du/dt-filter                                     Including CIT/COT (W:+400mm) **
NXC02616A2L0SSFA1A2 200     208 312 250 261 FR10/IP21 606x2275x605 341
NXC02616A5L0SSFA1A2 200     208 312 250 261 FR10/IP54 606x2405x605 351
+ACH                                             Cabinet heater 50W                         1 x 50W*
+ACL                                             Cabinet light                                   *
+AMO                                            ICB motor operator                         including Open/Close push buttons on the door *
+CIT                                              Cabling Input Top                            Including COT (W:+400mm)
+DCM                                            Analog meter + curr.trafo                CT on L1
+DVM                                            Analog V-meter + sel.sw.                 For main voltages
+GPL                                             100mm base/plinth                         For basic drive ***
+ICB                                              Circuit breaker                                MCCB, not with ILS, IFU or IFD
+ICO                                              Contactor AC-1                               *
+IFD                                              Fuse Switch + aR fuses                    Not with ILS, IFU or ICB
+IFU                                              aR fuses & base                              Not with ILS, ICB or IFD
+ILS                                              Load Switch                                    Not with IFU, ICB or IFD
+MDC                                            Terminals for DC connect.                DC-connection / additional dc/brake chopper terminals
+OCM                                            Common mode chokes                     To be put on motor cable
+ODU                                            du/dt filter                                      Including CIT/COT (W:+400mm) **
NXC03256A2L0SSFA1A2 250     261 392 315 325 FR10/IP21 606x2275x605 371
NXC03256A5L0SSFA1A2 250     261 392 315 325 FR10/IP54 606x2405x605 381
+ACH                                             Cabinet heater 50W                         1 x 50W*
+ACL                                             Cabinet light                                   *
+AMO                                            ICB motor operator                         including Open/Close push buttons on the door *
+CIT                                              Cabling Input Top                            Including COT (W:+400mm)
+DCM                                            Analog meter + curr.trafo                CT on L1
+DVM                                            Analog V-meter + sel.sw.                 For main voltages
+GPL                                             100mm base/plinth                         For basic drive ***
+ICB                                              Circuit breaker                                MCCB, not with ILS, IFU or IFD
+ICO                                              Contactor AC-1                               *
+IFD                                              Fuse Switch + aR fuses                    Not with ILS, IFU or ICB
+IFU                                              aR fuses & base                              Not with ILS, ICB or IFD
+ILS                                              Load Switch                                    Not with IFU, ICB or IFD
+MDC                                            Terminals for DC connect.                DC-connection / additional dc/brake chopper terminals
+OCM                                            Common mode chokes                     To be put on motor cable
+ODU                                            du/dt filter                                      Including CIT/COT (W:+400mm) **
NXC03856A2L0SSFA1A2 315     325 488 355 385 FR10/IP21 606x2275x605 371
NXC03856A5L0SSFA1A2 315     325 488 355 385 FR10/IP54 606x2405x605 381
+ACH                                             Cabinet heater 50W                         1 x 50W*
+ACL                                             Cabinet light                                   *
+AMO                                            ICB motor operator                         including Open/Close push buttons on the door *
+CIT                                              Cabling Input Top                            Including COT (W:+400mm)
+DCM                                            Analog meter + curr.trafo                CT on L1
+DVM                                            Analog V-meter + sel.sw.                 For main voltages
+GPL                                             100mm base/plinth                         For basic drive ***
+ICB                                              Circuit breaker                                MCCB, not with ILS, IFU or IFD
+IFD                                              Fuse Switch + aR fuses                    Not with ILS, IFU or ICB
+IFU                                              aR fuses & base                              Not with ILS, ICB or IFD
+ICO                                              Contactor AC-1                               *
+ILS                                              Load Switch                                    Not with IFU, ICB or IFD
+MDC                                            Terminals for DC connect.                DC-connection / additional dc/brake chopper terminals
+OCM                                            Common mode chokes                     To be put on motor cable
+ODU                                            du/dt-filter                                     Including CIT/COT (W:+400mm) **
NXC04166A2L0SSFA1A2 * 315     325 488 400 416 FR10/IP21 606x2275x605 371
NXC04166A5L0SSFA1A2 * 315     325 488 400 416 FR10/IP54 606x2405x605 381
+ACH                                             Cabinet heater 50W                         1 x 50W**
+ACL                                             Cabinet light                                   **
+AMO                                            ICB motor operator                         including Open/Close push buttons on the door **
+CIT                                              Cabling Input Top                            Including COT (W:+400mm)
+DCM                                            Analog meter + curr.trafo                CT on L1
+DVM                                            Analog V-meter + sel.sw.                 For main voltages
+GPL                                             100mm base/plinth                         For basic drive ****
+ICB                                              Circuit breaker                                MCCB, not with ILS, IFU or IFD
+IFD                                              Fuse Switch + aR fuses                    Not with ILS, IFU or ICB
+IFU                                              aR fuses & base                              Not with ILS, ICB or IFD
+ICO                                              Contactor AC-1                               **
+ILS                                              Load Switch                                    Not with IFU, ICB or IFD
+MDC                                            Terminals for DC connect.                DC-connection / additional dc/brake chopper terminals
+OCM                                            Common mode chokes                     To be put on motor cable
+ODU                                            du/dt-filter                                     Including CIT/COT (W:+400mm) ***
NXC04606A2L0SSFA1A2 385     355 578 450 460 FR11/IP21 806x2275x605 577
NXC04606A5L0SSFA1A2 355     385 578 450 460 FR11/IP54 806x2405x605 590
+ACH                                             Cabinet heater 50W                         1 x 50W*
+ACL                                             Cabinet light                                   *
+AMO                                            ICB motor operator                         including Open/Close push buttons on the door *
+CIT                                              Cabling Input Top                            Including COT (W:+400mm)
+DCM                                            Analog meter + curr.trafo                CT on L1
+DVM                                            Analog V-meter + sel.sw.                 For main voltages
+GPL                                             100mm base/plinth                         For basic drive ***
+ICB                                              Circuit breaker                                MCCB, not with ILS, IFU or IFD
+ICO                                              Contactor AC-1                               *
+IFD                                              Fuse Switch + aR fuses                    Not with ILS, IFU or ICB
+IFU                                              aR fuses & base                              Not with ILS, ICB or IFD
+ILS                                              Load Switch                                    Not with IFU, ICB or IFD
+MDC                                            Terminals for DC connect.                DC-connection / additional dc/brake chopper terminals
+OCM                                            Common mode chokes                     To be put on motor cable
+ODU                                            du/dt-filter                                     Including CIT/COT (W:+400mm) **
NXC05026A2L0SSFA1A2 460     450 690 500 502 FR11/IP21 806x2275x605 524
NXC05026A5L0SSFA1A2 450     460 690 500 502 FR11/IP54 806x2405x605 537
+ACH                                             Cabinet heater 50W                         1 x 50W*
+ACL                                             Cabinet light                                   *
+AMO                                            ICB motor operator                         including Open/Close push buttons on the door *
+CIT                                              Cabling Input Top                            Including COT (W:+400mm)
+DCM                                            Analog meter + curr.trafo                CT on L1
+DVM                                            Analog V-meter + sel.sw.                 For main voltages
+GPL                                             100mm base/plinth                         For basic drive ***
+ICB                                              Circuit breaker                                MCCB, not with ILS, IFU or IFD
+ICO                                              Contactor AC-1                               *
+IFD                                              Fuse Switch + aR fuses                    Not with ILS, IFU or ICB
+IFU                                              aR fuses & base                              Not with ILS, ICB or IFD
+ILS                                              Load Switch                                    Not with IFU, ICB or IFD
+MDC                                            Terminals for DC connect.                DC-connection / additional dc/brake chopper terminals
+OCM                                            Common mode chokes                     To be put on motor cable
+ODU                                            du/dt-filter                                     Including CIT/COT (W:+400mm) **
NXC05906A2L0SSFA1A2 * 502     500 753 560 590 FR11/IP21 806x2275x605 577
NXC05906A5L0SSFA1A2 * 500     502 753 560 590 FR11/IP54 806x2445x605 590
+ACH                                             Cabinet heater 50W                         1 x 50W**
+ACL                                             Cabinet light                                   **
+AMO                                            ICB motor operator                         including Open/Close push buttons on the door **
+CIT                                              Cabling Input Top                            Including COT (W:+400mm)
+DCM                                            Analog meter + curr.trafo                CT on L1
+DVM                                            Analog V-meter + sel.sw.                 For main voltages
+GPL                                             100mm base/plinth                         For basic drive ****
+ICB                                              Circuit breaker                                MCCB, not with ILS, IFU or IFD *
+ICO                                              Contactor AC-1                               **
+IFD                                              Fuse Switch + aR fuses                    Not with ILS, IFU or ICB
+IFU                                              aR fuses & base                              Not with ILS, ICB or IFD
+ILS                                              Load Switch                                    Not with IFU, ICB or IFD
+MDC                                            Terminals for DC connect.                DC-connection / additional dc/brake chopper terminals
+OCM                                            Common mode chokes                     To be put on motor cable
+ODU                                            du/dt-filter                                     Including CIT/COT (W:+400mm) ***
NXC06506A2L0SSFA1A2 590     560 885 630 650 FR12/IP21 1206x2275x605 745
NXC06506A5L0SSFA1A2 560     590 885 630 650 FR12/IP54 1206x2405x605 765
+ACH                                             Cabinet heater 50W                         2 x 50W*
+ACL                                             Cabinet light                                   *
+CIT                                              Cabling Input Top                            Including COT (W:+400mm)
+DCM                                            Analog meter + curr.trafo                CT on L1
+DVM                                            Analog V-meter + sel.sw.                 For main voltages
+GPL                                             100mm base/plinth                         For basic drive ***
+ICB                                              Circuit breaker, including +AMO        MCCB, not with ILS, IFU or IFD *
+ICO                                              Contactor AC-1                               *
+IFD                                              Fuse Switch + aR fuses                    Not with ILS, IFU or ICB
+IFU                                              aR fuses & base                              Not with ILS, ICB or IFD
+ILS                                              Load Switch                                    Not with IFU, ICB or IFD
+MDC                                            Terminals for resistor connect.          Brake chopper terminals
+OCM                                            Common mode chokes                     To be put on motor cable
+ODU                                            du/dt-filter                                     Including CIT/COT (W:+400mm) **
NXC07506A2L0SSFA1A2 650     630 975 710 750 FR12/IP21 1206x2275x605 745
NXC07506A5L0SSFA1A2 630     650 975 710 750 FR12/IP54 1206x2405x605 765
+ACH                                             Cabinet heater 50W                         2 x 50W*
+ACL                                             Cabinet light                                   *
+CIT                                              Cabling Input Top                            Including COT (W:+400mm)
+DCM                                            Analog meter + curr.trafo                CT on L1
+DVM                                            Analog V-meter + sel.sw.                 For main voltages
+GPL                                             100mm base/plinth                         For basic drive ***
+ICB                                              Circuit breaker, including +AMO        MCCB, not with ILS, IFU or IFD *
+ICO                                              Contactor AC-1                               *
+IFD                                              Fuse Switch + aR fuses                    Not with ILS, IFU or ICB
+IFU                                              aR fuses & base Not wit h ILS, ICB or IFD
+ILS                                              Load Switch                                    Not with IFU, ICB or IFD
+MDC                                            Terminals for resistor connect.          Brake chopper terminals
+OCM                                            Common mode chokes                     To be put on motor cable
+ODU                                            du/dt-filter                                     Including CIT/COT (W:+400mm) **
NXC08206A2L0SSFA1A2 * 750     710 975 800 820 FR12/IP21 1206x2275x605 745
NXC08206A5L0SSFA1A2 * 710     750 975 800 820 FR12/IP54 1206x2405x605 765
+ACH                                             Cabinet heater 50W                         2 x 50W**
+ACL                                             Cabinet light                                   **
+CIT                                              Cabling Input Top                            Including COT (W:+400mm)
+DCM                                            Analog meter + curr.trafo                CT on L1
+DVM                                            Analog V-meter + sel.sw.                 For main voltages
+GPL                                             100mm base/plinth                         For basic drive ****
+ICB                                              Circuit breaker, including +AMO        MCCB, not with ILS, IFU or IFD **
+ICO                                              Contactor AC-1                               **
+IFD                                              Fuse Switch + aR fuses                    Not with ILS, IFU or ICB
+IFU                                              aR fuses & base Not wit h ILS, ICB or IFD
+ILS                                              Load Switch                                    Not with IFU, ICB or IFD
+MDC                                            Terminals for resistor connect.          Brake chopper terminals
+OCM                                            Common mode chokes                     To be put on motor cable
+ODU                                            du/dt-filter                                     Including CIT/COT (W:+400mm) ***
NXC09206A2N0SSFA1A2 +IFD 800     820 1230 900       920 FR13/IP21 1406x2275x605 1050
NXC09206A5N0SSFA1A2 +IFD 800     820 1230 900       920 FR13/IP54 1406x2405x605 1060
+ACH                                             Cabinet heater 50W                         2 x 50W*
+ACL                                             Cabinet light                                   *
+CIT                                              Cabling Input Top                            Including COT (W:+400mm)
+DCM                                            Analog meter + curr.trafo                CT on L1
+DVM                                            Analog V-meter + sel.sw.                 For main voltages
+GPL                                             100mm base/plinth                         For basic drive **
+ICB                                              Circuit breaker, including +AMO        MCCB; not with +IFD, this option upgrades +IFD to +ICB *
+MDC                                            Terminals for DC connect.                Including COT (W:+400mm)
+OCM                                            Common mode chokes                     To be put on motor cable
+ODU                                            du/dt-filter
NXC10306A2N0SSFA1A2 +IFD 900     920 1380 1000     1030 FR13/IP21 1406x2275x605 1050
NXC10306A5N0SSFA1A2 +IFD 900     920 1380 1000     1030 FR13/IP54 1406x2405x605 1060
+ACH                                             Cabinet heater 50W                         2 x 50W*
+ACL                                             Cabinet light                                   *
+CIT                                              Cabling Input Top                            Including COT (W:+400mm)
+DCM                                            Analog meter + curr.trafo                CT on L1
+DVM                                            Analog V-meter + sel.sw.                 For main voltages
+GPL                                             100mm base/plinth                         For basic drive **
+ICB                                              Circuit breaker, including +AMO        MCCB; not with +IFD, this option upgrades +IFD to +ICB *
+MDC                                            Terminals for DC connect.                Including COT (W:+400mm)
+OCM                                            Common mode chokes                     To be put on motor cable
+ODU                                            du/dt-filter
NXC11806A2N0SSFA1A2 +IFD* 1000   1030 1463 1150     1180 FR13/IP21 1406x2275x605 1050
NXC11806A5N0SSFA1A2 +IFD* 1000   1030 1463 1150     1180 FR13/IP54 1406x2405x605 1060
+ACH                                             Cabinet heater 50W                         2 x 50W**
+ACL                                             Cabinet light                                   **
+CIT                                              Cabling Input Top                            Including COT (W:+400mm)
+DCM                                            Analog meter + curr.trafo                CT on L1
+DVM                                            Analog V-meter + sel.sw.                 For main voltages
+GPL                                             100mm base/plinth                         For basic drive ***
+ICB                                              Circuit breaker, including +AMO        MCCB; not with +IFD, this option upgrades +IFD to +ICB *
+MDC                                            Terminals for DC connect.                Including COT (W:+400mm)
+OCM                                            Common mode chokes                     To be put on motor cable
+ODU                                            du/dt-filter
NXC10306A2N0SSFA1A2 +IFD 900     920 1380 1000     1030 FR13/IP21 1406x2275x605 1050
NXC10306A5N0SSFA1A2 +IFD 900     920 1380 1000     1030 FR13/IP54 1406x2405x605 1060
+ACH                                             Cabinet heater 50W                         2 x 50W*
+ACL                                             Cabinet light                                   *
+CIT                                              Cabling Input Top                            Including COT (W:+400mm)
+DCM                                            Analog meter + curr.trafo                CT on L1
+DVM                                            Analog V-meter + sel.sw.                 For main voltages
+GPL                                             100mm base/plinth                         For each G40/G60/G80, (H:+100mm)
+ICB                                              Circuit breaker, including +AMO        MCCB
+MDC                                            Terminals for DC connect.                Including COT (W:+400mm)
+OCM                                            Common mode chokes                     To be put on motor cable
+ODU                                            dUdt-filter                                      Including COT (W:+400mm)
NXC11806A2N0SSFA1A2 +IFD** 1000   1030 1463 1150     1180 FR13/IP21 1406x2275x605 1050
NXC11806A5N0SSFA1A2 +IFD** 1000   1030 1463 1150     1180 FR13/IP54 1406x2405x605 1060
+ACH                                             Cabinet heater 50W                         2 x 50W*
+ACL                                             Cabinet light                                   *
+CIT                                              Cabling Input Top                            Including COT (W:+400mm)
+DCM                                            Analog meter + curr.trafo                CT on L1
+DVM                                            Analog V-meter + sel.sw.                 For main voltages
+GPL                                             100mm base/plinth                         For each G40/G60/G80, (H:+100mm)
+ICB                                              Circuit breaker, including +AMO        MCCB
+MDC                                            Terminals for DC connect.                Including COT (W:+400mm)
+OCM                                            Common mode chokes                     To be put on motor cable
+ODU                                            dUdt-filter                                      Including COT (W:+400mm)
NXC15006A2N0SSFA1A2 +ICB +AMO 1300   1300 1950 1500     1500 FR14/IP21 2406x2275x605 1950
NXC15006A5N0SSFA1A2 +ICB +AMO 1300   1300 1950 1500     1500 FR14/IP54 2406x2405x605 1980
+ACH                                             Cabinet heater 50W                         2 x 50W*
+ACL                                             Cabinet light                                   *
+CIT                                              Cabling Input Top                            Including COT (W:+400mm)
+DCM                                            Analog meter + curr.trafo                CT on L1
+DVM                                            Analog V-meter + sel.sw.                 For main voltages
+GPL                                             100mm base/plinth                         For each G40/G60/G80, (H:+100mm)
+OCM                                            Common mode chokes                     To be put on motor cable
+ODU                                            dUdt-filter                                      Including COT (W:+400mm)
NXC19006A2N0SSFA1A2 +ICB +AMO 1500   1500 2250 1800     1900 FR14/IP21 2806x2275x605 2250
NXC19006A5N0SSFA1A2 +ICB +AMO 1500   1500 2250 1800     1900 FR14/IP54 2806x2405x605 2280
+ACH                                             Cabinet heater 50W                         2 x 50W*
+ACL                                             Cabinet light                                   *
+CIT                                              Cabling Input Top                            Including COT (W:+400mm)
+DCM                                            Analog meter + curr.trafo                CT on L1
+DVM                                            Analog V-meter + sel.sw.                 For main voltages
+GPL                                             100mm base/plinth                         For each G40/G60/G80, (H:+100mm)
+OCM                                            Common mode chokes                     To be put on motor cable
+ODU                                            dUdt-filter                                      Including COT (W:+400mm)
NXC22506A2N0SSFA1A2 +ICB +AMO 1800   1900 2782 2000     2250 FR14/IP21 2806x2275x605 2300
NXC22506A5N0SSFA1A2 +ICB +AMO 1800   1900 2782 2000     2250 FR14/IP54 2806x2405x605 2330
+ACH                                             Cabinet heater 50W                         2 x 50W*
+ACL                                             Cabinet light                                   *
+CIT                                              Cabling Input Top                            Including COT (W:+400mm)
+DCM                                            Analog meter + curr.trafo                CT on L1
+DVM                                            Analog V-meter + sel.sw.                 For main voltages
+GPL                                             100mm base/plinth                         For each G40/G60/G80, (H:+100mm)
+OCM                                            Common mode chokes                     To be put on motor cable
+ODU                                            dUdt-filter                                      Including COT (W:+400mm)
NXC02616A2L0TSFA1A2 200 208 312 250 261 FR10/IP21 606x2275x605 341
NXC02616A5L0TSFA1A2 200 208 312 250 261 FR10/IP54 606x2405x605 351
+ACH                                                          Cabinet heater 50W                             1 x 50W*
+ACL                                                          Cabinet light                                       *
+AMO                                                         ICB motor operator                             including Open/Close push buttons on the door *
+CIT                                                           Cabling Input Top                                Including COT (W:+400mm)
+DCM                                                         Analog meter + curr.trafo                    CT on L1
+DVM                                                         Analog V-meter + sel.sw.                     For main voltages
+GPL                                                          100mm base/plinth                             For basic drive ***
+ICB                                                           Circuit breaker                                    MCCB, not with IFU *
+IFU                                                           aR fuses & base                                  Not with ICB
+OCM                                                         Common mode chokes                         To be put on motor cable
+ODU                                                         du/dt-filter                                         Including CIT/COT (W:+400mm) **
NXC03256A2L0TSFA1A2 250 261 392 315 325 FR10/IP21 606x2275x605 371
NXC03256A5L0TSFA1A2 250 261 392 315 325 FR10/IP54 606x2405x605 381
+ACH                                                          Cabinet heater 50W                             1 x 50W*
+ACL                                                          Cabinet light                                       *
+AMO                                                         ICB motor operator                             including Open/Close push buttons on the door *
+CIT                                                           Cabling Input Top                                Including COT (W:+400mm)
+DCM                                                         Analog meter + curr.trafo                    CT on L1
+DVM                                                         Analog V-meter + sel.sw.                     For main voltages
+GPL                                                          100mm base/plinth                             For basic drive ***
+ICB                                                           Circuit breaker                                    MCCB, not with IFU *
+IFU                                                           aR fuses & base                                  Not with ICB
+OCM                                                         Common mode chokes                         To be put on motor cable
+ODU                                                         du/dt-filter                                          Including CIT/COT (W:+400mm) **
NXC03856A2L0TSFA1A2 315 325 488 355 385 FR10/IP21 606x2275x605 371
NXC03856A5L0TSFA1A2 315 325 488 355 385 FR10/IP54 606x2405x605 381
+ACH                                                          Cabinet heater 50W                             1 x 50W*
+ACL                                                          Cabinet light                                       *
+AMO                                                         ICB motor operator                             including Open/Close push buttons on the door *
+CIT                                                           Cabling Input Top                                Including COT (W:+400mm)
+DCM                                                         Analog meter + curr.trafo                    CT on L1
+DVM                                                         Analog V-meter + sel.sw.                     For main voltages
+GPL                                                          100mm base/plinth                             For basic drive ***
+ICB                                                           Circuit breaker                                    MCCB, not with IFU *
+IFU                                                           aR fuses & base                                  Not with ICB
+OCM                                                         Common mode chokes                         To be put on motor cable
+ODU                                                         du/dt-filter                                          Including CIT/COT (W:+400mm) **
NXC04166A2L0TSFA1A2 * 315 325 488 400 416 FR10/IP21 606x2275x605 371
NXC04166A5L0TSFA1A2 * 315 325 488 400 416 FR10/IP54 606x2405x605 381
+ACH                                                          Cabinet heater 50W                             1 x 50W**
+ACL                                                          Cabinet light                                       **
+AMO                                                         ICB motor operator                             including Open/Close push buttons on the door **
+CIT                                                           Cabling Input Top                                Including COT (W:+400mm)
+DCM                                                         Analog meter + curr.trafo                    CT on L1
+DVM                                                         Analog V-meter + sel.sw.                     For main voltages
+GPL                                                          100mm base/plinth                             For basic drive ****
+ICB                                                           Circuit breaker                                    MCCB, not with IFU *
+IFU                                                           aR fuses & base                                  Not with ICB
+OCM                                                         Common mode chokes                         To be put on motor cable
+ODU                                                         du/dt-filter                                          Including CIT/COT (W:+400mm) ***
NXC04606A2L0TSFA1A2 355 385 578 450 460 FR11/IP21 806x2275x605 524
NXC04606A5L0TSFA1A2 355 385 578 450 460 FR11/IP54 806x2405x605 537
+ACH                                                          Cabinet heater 50W                             1 x 50W*
+ACL                                                          Cabinet light                                       *
+AMO                                                         ICB motor operator                             including Open/Close push buttons on the door *
+CIT                                                           Cabling Input Top                                Including COT (W:+400mm)
+DCM                                                         Analog meter + curr.trafo                    CT on L1
+DVM                                                         Analog V-meter + sel.sw.                     For main voltages
+GPL                                                          100mm base/plinth                             For basic drive ***
+ICB                                                           Circuit breaker                                    MCCB, not with ILS, IFU or IFD *
+ICO                                                          Contactor AC-1                                   *
+IFD                                                           Fuse Switch + aR fuses                        Not with ILS, IFU or ICB
+IFU                                                           aR fuses & base                                  Not with ILS, IFD or ICB
+ILS                                                           Load Switch 630A                                Not with ICB, IFU or IFD
+OCM                                                         Common mode chokes                         To be put on motor cable
+ODU                                                         du/dt-filter                                          Including CIT/COT (W:+400mm) **
NXC05026A2L0TSFA1A2 450 460 690 500 502 FR11/IP21 806x2275x605 524
NXC05026A5L0TSFA1A2 450 460 690 500 502 FR11/IP54 806x2405x605 537
+ACH                                                          Cabinet heater 50W                             1 x 50W*
+ACL                                                          Cabinet light                                       *
+AMO                                                         ICB motor operator                             including Open/Close push buttons on the door *
+CIT                                                           Cabling Input Top                                Including COT (W:+400mm)
+DCM                                                         Analog meter + curr.trafo                    CT on L1
+DVM                                                         Analog V-meter + sel.sw.                     For main voltages
+GPL                                                          100mm base/plinth                             For basic drive ***
+ICB                                                           Circuit breaker                                    MCCB, not with ILS, IFU or IFD *
+ICO                                                          Contactor AC-1                                   *
+IFD                                                           Fuse Switch + aR fuses                        Not with ILS, IFU or ICB
+IFU                                                           aR fuses & base                                  Not with ILS, IFD or ICB
+ILS                                                           Load Switch 630A                                Not with ICB, IFU or IFD
+OCM                                                         Common mode chokes                         To be put on motor cable
+ODU                                                         du/dt-filter                                          Including CIT/COT (W:+400mm) **
NXC05906A2L0TSFA1A2 * 500 502 753 560 590 FR11/IP21 806x2275x605 577
NXC05906A5L0TSFA1A2 * 500 502 753 560 590 FR11/IP54 806x2445x605 590
+ACH                                                          Cabinet heater 50W                             1 x 50W**
+ACL                                                          Cabinet light                                       **
+AMO                                                         ICB motor operator                             including Open/Close push buttons on the door **
+CIT                                                           Cabling Input Top                                Including COT (W:+400mm)
+DCM                                                         Analog meter + curr.trafo                    CT on L1
+DVM                                                         Analog V-meter + sel.sw.                     For main voltages
+GPL                                                          100mm base/plinth                             For basic drive ****
+ICB                                                           Circuit breaker                                    MCCB, not with ILS, IFU or IFD **
+ICO                                                          Contactor AC-1                                   **
+IFD                                                           Fuse Switch + aR fuses                        Not with ILS, IFU or ICB
+IFU                                                           aR fuses & base                                  Not with ILS, IFD or ICB
+ILS                                                           Load Switch 630A                                Not with ICB, IFU or IFD
+OCM                                                         Common mode chokes                         To be put on motor cable
+ODU                                                         du/dt-filter                                          Including CIT/COT (W:+400mm) ***
NXC06506A2L0TSFA1A2 560 590 885 630 650 FR12/IP21 1206x2275x605 745
NXC06506A5L0TSFA1A2 560 590 885 630 650 FR12/IP54 1206x2405x605 765
+ACH                                                          Cabinet heater 50W                             1 x 50W*
+ACL                                                          Cabinet light                                       *
+CIT                                                           Cabling Input Top                                Including COT (W:+400mm)
+DCM                                                         Analog meter + curr.trafo                    CT on L1
+DVM                                                         Analog V-meter + sel.sw.                     For main voltages
+GPL                                                          100mm base/plinth                             For basic drive ***
+ICB                                                           Circuit breaker, including +AMO            MCCB, not with ILS, IFU or IFD *
+ICO                                                          Contactor AC-1                                   *
+IFD                                                           Fuse Switch + aR fuses                        Not with ILS, IFU or ICB
+IFU                                                           aR fuses & base                                  Not with ILS, IFD or ICB
+ILS                                                           Load Switch 630A                                Not with ICB, IFU or IFD
+OCM                                                         Common mode chokes                         To be put on motor cable
+ODU                                                         du/dt-filter                                          Including CIT/COT (W:+400mm) **
NXC07506A2L0TSFA1A2 630 650 975 710 750 FR12/IP21 1206x2275x605 745
NXC07506A5L0TSFA1A2 630 650 975 710 750 FR12/IP54 1206x2405x605 765
+ACH                                                          Cabinet heater 50W                             1 x 50W*
+ACL                                                          Cabinet light                                       *
+CIT                                                           Cabling Input Top                                Including COT (W:+400mm)
+DCM                                                         Analog meter + curr.trafo                    CT on L1
+DVM                                                         Analog V-meter + sel.sw.                     For main voltages
+GPL                                                          100mm base/plinth                             For basic drive ***
+ICB                                                           Circuit breaker, including +AMO            MCCB, not with ILS, IFU or IFD *
+ICO                                                          Contactor AC-1                                   *
+IFD                                                           Fuse Switch + aR fuses                        Not with ILS, IFU or ICB
+IFU                                                           aR fuses & base                                  Not with ILS, IFD or ICB
+ILS                                                           Load Switch 630A                                Not with ICB, IFU or IFD
+OCM                                                         Common mode chokes                         To be put on motor cable
+ODU                                                         du/dt-filter                                          Including CIT/COT (W:+400mm) **
NXC08206A2L0TSFA1A2 * 650 750 975 800 820 FR12/IP21 1206x2275x605 745
NXC08206A5L0TSFA1A2 * 650 750 975 800 820 FR12/IP54 1206x2405x605 765
+ACH                                                          Cabinet heater 50W                             1 x 50W**
+ACL                                                          Cabinet light                                       **
+CIT                                                           Cabling Input Top                                Including COT (W:+400mm)
+DCM                                                         Analog meter + curr.trafo                    CT on L1
+DVM                                                         Analog V-meter + sel.sw.                     For main voltages
+GPL                                                          100mm base/plinth                             For basic drive ****
+ICB                                                           Circuit breaker, including +AMO            MCCB, not with ILS, IFU or IFD **
+ICO                                                          Contactor AC-1                                   **
+IFD                                                           Fuse Switch + aR fuses                        Not with ILS, IFU or ICB
+IFU                                                           aR fuses & base                                  Not with ILS, IFD or ICB
+ILS                                                           Load Switch 630A                                Not with ICB, IFU or IFD
+OCM                                                         Common mode chokes                         To be put on motor cable
+ODU                                                         du/dt-filter                                          Including CIT/COT (W:+400mm) ***
NXC09206A2L0TSFA1A2 +ICB +AMO 800 820 1230 900 920 FR13/IP21 1406x2275x605 1050
NXC09206A5L0TSFA1A2 +ICB +AMO 800 820 1230 900 920 FR13/IP54 1406x2405x605 1060
+ACH                                                          Cabinet heater 50W                             1 x 50W*
+ACL                                                          Cabinet light                                       *
+CIT                                                           Cabling Input Top                                Including COT (W:+400mm)
+DCM                                                         Analog meter + curr.trafo                    CT on L1
+DVM                                                         Analog V-meter + sel.sw.                     For main voltages
+GPL                                                          100mm base/plinth                             For basic drive **
+OCM                                                         Common mode chokes                         To be put on motor cable
+ODU                                                         du/dt-filter
NXC10306A2L0TSFA1A2 +ICB +AMO 900 920 1380 1000 1030 FR13/IP21 1406x2275x605 1050
NXC10306A5L0TSFA1A2 +ICB +AMO 900 920 1380 1000 1030 FR13/IP54 1406x2405x605 1060
+ACH                                                          Cabinet heater 50W                             1 x 50W*
+ACL                                                          Cabinet light                                       *
+CIT                                                           Cabling Input Top                                Including COT (W:+400mm)
+DCM                                                         Analog meter + curr.trafo                    CT on L1
+DVM                                                         Analog V-meter + sel.sw.                     For main voltages
+GPL                                                          100mm base/plinth                             For basic drive **
+OCM                                                         Common mode chokes                         To be put on motor cable
+ODU                                                         du/dt-filter
NXC11806A2L0TSFA1A2 +ICB +AMO* 1000     1030 1463 1150 1180 FR13/IP21 1406x2275x605 1050
NXC11806A5L0TSFA1A2 +ICB +AMO* 1000     1030 1463 1150 1180 FR13/IP54 1406x2405x605 1060
+ACH                                                          Cabinet heater 50W                             1 x 50W**
+ACL                                                          Cabinet light                                       **
+CIT                                                           Cabling Input Top                                Including COT (W:+400mm)
+DCM                                                         Analog meter + curr.trafo                    CT on L1
+DVM                                                         Analog V-meter + sel.sw.                     For main voltages
+GPL                                                          100mm base/plinth                             For basic drive ***
+OCM                                                         Common mode chokes                         To be put on motor cable
+ODU                                                         du/dt-filter
NXC15006A2N0TSFA1A2 +ICB +AMO 1300     1300 1950 1500 1500 FR14/IP21 2806x2275x605 2250
NXC15006A5N0TSFA1A2 +ICB +AMO 1300     1300 1950 1500 1500 FR14/IP54 2806x2405x605 2280
+ACH                                                          Cabinet heater 50W                             2 x 50W*
+ACL                                                          Cabinet light                                       *
+CIT                                                           Cabling Input Top                                Including COT (W:+400mm)
+DCM                                                         Analog meter + curr.trafo                    CT on L1
+DVM                                                         Analog V-meter + sel.sw.                     For main voltages
+GPL                                                          100mm base/plinth                             For each G40/G60/G80, (H:+100mm)
+OCM                                                         Common mode chokes                         To be put on motor cable
+ODU                                                         dUdt-filter                                           Including COT (W:+400mm)
NXC19006A2N0TSFA1A2 +ICB +AMO 1500     1500 2250 1800 1900 FR14/IP21 2806x2275x605 2250
NXC19006A5N0TSFA1A2 +ICB +AMO 1500     1500 2250 1800 1900 FR14/IP54 2806x2405x605 2280
+ACH                                                          Cabinet heater 50W                             2 x 50W*
+ACL                                                          Cabinet light                                       *
+CIT                                                           Cabling Input Top                                Including COT (W:+400mm)
+DCM                                                         Analog meter + curr.trafo                    CT on L1
+DVM                                                         Analog V-meter + sel.sw.                     For main voltages
+GPL                                                          100mm base/plinth                             For each G40/G60/G80, (H:+100mm)
+OCM                                                         Common mode chokes                         To be put on motor cable
+ODU                                                         dUdt-filter                                           Including COT (W:+400mm)
NXC22506A2N0TSFA1A2 +ICB +AMO** 1800     1900 2782 2000 2250 FR14/IP21 2806x2275x605 2300
NXC22506A5N0TSFA1A2 +ICB +AMO** 1800     1900 2782 2000 2250 FR14/IP54 2806x2405x605 2330
+ACH                                                          Cabinet heater 50W                             2 x 50W*
+ACL                                                          Cabinet light                                       *
+CIT                                                           Cabling Input Top                                Including COT (W:+400mm)
+DCM                                                         Analog meter + curr.trafo                    CT on L1
+DVM                                                         Analog V-meter + sel.sw.                     For main voltages
+GPL                                                          100mm base/plinth                             For each G40/G60/G80, (H:+100mm)
+OCM                                                         Common mode chokes                         To be put on motor cable
+ODU                                                         dUdt-filter                                           Including COT (W:+400mm)
+AAA                 Aux. contact (for +ATx supervision)                  Wired to DIN3
+AAC                 Aux. contact (for +Ixx options)                        Wired to DIN3, mounted on ICO if ordered, otherwise  on other input device
+AAI                  Analog signal isolator                                       Order: 1st AI1, 2nd AO, 3rd AI2
+ACR                 Control relay                                                   wired to DO1, If > 3pcs then FR13 requires +G40 (widht +400mm)  or +CIT/+COT
+ACS                 230VAC customer socket                                 requires TUP
+ADC                 Power supply 24VDC 2,5A                                24VDC to control, req. TUP
+AMB                 Mech. brake control                                         400V, 4kVA, to RO2, FR13 requires +G40 (widht +400mm)  or +CIT/+COT
+AMF                 Motor fan control                                             400V, 4kVA, to RO1, FR13 requires +G40 (widht +400mm)  or +CIT/+COT
+AMH                 Motor heater feeder                                         230V, 10A, to RO1
+AT1                  Aux.trafo 200VA 400V* or 690V */230V           Min. size for FR10 + ICO
+AT2                  Aux.trafo 750VA 400V* or 690V* /230V           Min. size for FR11 & FR12 + ICO
+AT3                  Aux.trafo 2500VA 400V* or 690V* /230V
+AT4                  Aux.trafo 4000VA 400V* or 690V* /230V          FR13 requires +G40 (widht +400mm)  or +CIT/+COT
+DAM                 Analog meter (AO1)                                        Wired to AO1
+DAR                 Potentiometer for ref.                                      Wired to AIN1
+DCO                 MC operation switch                                        Wired to ICO if mounted,  otherwise  to Tlx
+DEP                  Em. push-button                                             Wired to EMS-relay  if mounted,  otherwise  to Tlx
+DLD                 Pilot light (DO1)                                              Wired to DO1
+DLF                  Pilot light (FLT)                                               Wired to RO2
+DLR                  Pilot light (RUN)                                              Wired to RO1
+DLV                  Pilot light(Contr vol on)                                    Requires TUP
+DRO                 Local / Remote op. switch                                Wired to DIN6, requires Local/Remote Application
+DRP                 Reset push-button                                           Wired to DIN6
+TIO Terminal I/O 35pcs A1+A2/A3  boards only
+TID Terminal I/O 70pcs A1+A2/A3  boards only
+TUP Separate 230VAC term.  
+G40                 400mm empty cabinet                                     Empty section
+G60                 600mm empty cabinet                                     Empty section
+G80                 800mm empty cabinet                                     Empty section
+GPL                  100mm base/plinth                                         For each G40/G60/G80, (H:+100mm)
+PES                  Em. stop (cat 0)                                              Not with PED, requires TUP, FR13 requires +G40 (widht +400mm)  or +CIT/+COT
+PED                  Em. stop (cat 1)                                              Not with PES, requires TUP, FR13 requires +G40 (widht +400mm)  or +CIT/+COT
+PTR                  Thermistor relay                                              PTB approved
+PAP                  Arc protection system                                      Including  two ARC sensors, FR13 requires +G40 (widht +400mm)  or +CIT/+COT
+PIF                   Insulation fault sensor                                     For IT networks,  FR13 requires +G40 (widht +400mm)  or +CIT/+COT
NXI_0004 5                            1,1          3,3                            1,5         4,3             FR4/IP00                128x292x190                                                     5
NXI_0009 5                             3           7,6                             4            9              FR4/IP00                128x292x190                                                     5
NXI_0012 5                             4             9                             5,5          12             FR4/IP00                128x292x190                                                     5
NXI_0016 5                            5,5           12                            7,5          16             FR6/IP00                195x519x237                                                    16
NXI_0022 5                            7,5           16                             11          23             FR6/IP00                195x519x237                                                    16
NXI_0031 5                            11           23                             15          31             FR6/IP00                195x519x237                                                    16
NXI_0038 5                            15           31                            18,5         38             FR6/IP00                195x519x237                                                    16
NXI_0045 5                           18,5          38                             22          46             FR6/IP00                195x519x237                                                    16
NXI_0061 5                            22           46                             30          61             FR7/IP00                237x591x257                                                    29
NXI_0072 5                            30           61                             37          72             FR7/IP00                237x591x257                                                    29
NXI_0087 5                            37           72                             45          87             FR7/IP00                237x591x257                                                    29
NXI_0105 5                            45           87                             55         105             FR7/IP00                237x591x257                                                    29
NXI_0140 5                            55          105                            75         140             FR8/IP00                289x758x344                                                    48
NXI_0168 5                            75          140                            90         170             FI9/IP00                 289x758x344                                                    67
NXI_0205 5                            90          170                           110        205             FI9/IP00                 289x758x344                                                    67
NXI_0261 5                           110         205                           132        261             FI9/IP00                239x1030x372                                                    67
NXI_0300 5                           132         245                           160        300             FI9/IP00                239x1030x372                                                    67
NXI_0385 5                           160         300                           200        385            FI10/IP00               239x1032x552                                                   100
NXI_0460 5                           200         385                           250        460            FI10/IP00               239x1032x552                                                   100
NXI_0520 5                           250         460                           250        520            FI10/IP00               239x1032x552                                                   100
NXI_0590 5                           250         520                           315        590            FI12/IP00            (2x239)x1032x552                                                200
NXI_0650 5                           315         590                           355        650            FI12/IP00            (2x239)x1032x552                                                200
NXI_0730 5                           355         650                           400        730            FI12/IP00            (2x239)x1032x552                                                200
NXI_0820 5                           400         730                           450        820            FI12/IP00            (2x239)x1032x552                                                200
NXI_0920 5                           450         820                           500        920            FI12/IP00            (2x239)x1032x552                                                200
NXI_1030 5                           500         920                           560        1030           FI12/IP00            (2x239)x1032x552                                                200
NXI_1150 5                           560        1030                          630        1150           FI13/IP00               708x1032x553                                                   306
NXI_1300 5                           630        1150                          710        1300           FI13/IP00               708x1032x553                                                   306
NXI_1450 5                           710        1300                          800        1450           FI13/IP00               708x1032x553                                                   306
NXI_1770 5                           900        1600                         1000       1770           FI14/IP00            (2x708)x1032x553                                                612
NXI_2150 5                          1100        1940                         1200       2150           FI14/IP00            (2x708)x1032x553                                                612
NXI_2700 5                          1200        2300                         1500       2700           FI14/IP00            (2x708)x1032x553                                                612
NXI_0004 6                            2,2          3,2                             3           4,5                   FR6/IP00          195x519x237                                                    16
NXI_0005 6                             3           4,5                             4           5,5                   FR6/IP00          195x519x237                                                    16
NXI_0007 6                             4           5,5                            5,5         7,5                   FR6/IP00          195x519x237                                                    16
NXI_0010 6                            5,5          7,5                            7,5          10                   FR6/IP00          195x519x237                                                    16
NXI_0013 6                            7,5           10                             11         13,5                  FR6/IP00          195x519x237                                                    16
NXI_0018 6                            11          13,5                            15          18                   FR6/IP00          195x519x237                                                    16
NXI_0022 6                            15           18                            18,5         22                   FR6/IP00          195x519x237                                                    16
NXI_0027 6                           18,5          22                             22          27                    FR6/IP00          195x519x237                                                    16
NXI_0034 6                            22           27                             30          34                    FR6/IP00          195x519x237                                                    16
NXI_0041 6                            30           34                             37          41                    FR7/IP00          237x591x257                                                    29
NXI_0052 6                            37           41                             45          52                    FR7/IP00          237x591x257                                                    29
NXI_0062 6                            45           52                             55          62                    FR8/IP00          289x758x344                                                    48
NXI_0080 6                            55           62                             75          80                    FR8/IP00          289x758x344                                                    48
NXI_0100 6                            75           80                             90         100                   FR8/IP00          289x758x344                                                    48
NXI_0125 6                            90          100                           110        125                   FI9/IP00         239x1030x372                                                    67
NXI_0144 6                           110         125                           132        144                   FI9/IP00         239x1030x372                                                    67
NXI_0170 6                           132         144                           160        170                   FI9/IP00         239x1030x372                                                    67
NXI_0208 6                           160         170                           200        208                   FI9/IP00         239x1030x372                                                    67
NXI_0261 6                           200         208                           250        261                  FI10/IP00         239x1032x552                                                   100
NXI_0325 6                           250         261                           315        325                  FI10/IP00         239x1032x552                                                   100
NXI_0385 6                           315         325                           355        385                  FI10/IP00         239x1032x552                                                   100
NXI_0416 6                           315         325                           400        416                  FI10/IP00         239x1032x552                                                   100
NXI_0460 6                           355         385                           450        460                  FI12/IP00      (2x239)x1032x552                                                200
NXI_0502 6                           450         460                           500        502                  FI12/IP00      (2x239)x1032x552                                                200
NXI_0590 6                           500         502                           560        590                  FI12/IP00      (2x239)x1032x552                                                200
NXI_0650 6                           560         590                           630        650                  FI12/IP00      (2x239)x1032x552                                                200
NXI_0750 6                           630         650                           710        750                  FI12/IP00      (2x239)x1032x552                                                200
NXI_0820 6                           630         650                           800        820                  FI12/IP00      (2x239)x1032x552                                                200
NXI_0920 6                           800         820                           900        920                  FI13/IP00         708x1032x553                                                   306
NXI_1030 6                           900         920                          1000       1030                 FI13/IP00         708x1032x553                                                   306
NXI_1180 6                          1000        1030                         1150       1180                 FI13/IP00         708x1032x553                                                   306
NXI_1500 6                          1300        1300                         1500       1500                 FI14/IP00      (2x708)x1032x553                                                612
NXI_1900 6                          1500        1500                         1800       1900                 FI14/IP00      (2x708)x1032x553                                                612
NXI_2250 6                          1800        1900                         2000       2250                 FI14/IP00      (2x708)x1032x553                                                612
NXA_0261 5                           110         205                           132        261                   FI9/IP00         239x1030x372                                                    67
NXA_0460 5                           200         385                           250        460                  FI10/IP00         239x1032x552                                                   100
NXA_0920 5                           450         820                           500        920                  FI12/IP00      (2x239)x1032x552                                                200
NXA_1300 5                           630        1150                          710        1300                 FI13/IP00         708x1032x553                                                   306
NXA_2150 5                          1100        1940                         1200       2150                 FI14/IP00      (2x708)x1032x553                                                612
NXA_0170 6                           132         144                           160        170                   FI9/IP00         239x1030x372                                                    67
NXA_0385 6                           315         325                           355        385                  FI10/IP00         239x1032x552                                                   100
NXA_0750 6                           630         650                           710        750                  FI12/IP00      (2x239)x1032x552                                                200
NXA_1030 6                           900         920                          1000       1030                 FI13/IP00         708x1032x553                                                   306
NXA_1900 6                          1500        1500                         1800       1900                 FI14/IP00      (2x708)x1032x553                                                612
NXF_0300 5                           132         245                           160        300                   FI9/IP00         239x1030x372                                                    67
NXF_0520 5                           250         460                           250        520                  FI10/IP00         239x1032x552                                                   100
NXF_1030 5                           500         920                           560        1030                 FI12/IP00      (2x239)x1032x552                                                200
NXF_1450 5                           710        1300                          800        1450                 FI13/IP00         708x1032x553                                                   306
NXF_2700 5                          1200        2300                         1500       2700                 FI14/IP00      (2x708)x1032x553                                                612
NXF_0208 6                           160         170                           200        208                   FI9/IP00         239x1030x372                                                    67
NXF_0416 6                           315         325                           400        416                  FI10/IP00         239x1032x552                                                   100
NXF_0820 6                           630         650                           800        820                  FI12/IP00      (2x239)x1032x552                                                200
NXF_1180 6                          1000        1030                         1150       1180                 FI13/IP00         708x1032x553                                                   306
NXF_2250 6                          1800        1900                         2000       2250                 FI14/IP00      (2x708)x1032x553                                                612
NXP00165A0N1SWSA1A2                16             15               11                 7,5                   11              0,4/0,2/0,6         CH3/IP00       160x431x240            30
NXP00225A0N1SWSA1A2                22             20               15                  11                   15              0,5/0,2/0,7         CH3/IP00       160x431x240            30
NXP00315A0N1SWSA1A2                31             28               21                  15                  18,5             0,7/0,2/0,9         CH3/IP00       160x431x240            30
NXP00385A0N1SWSA1A2                38             35               25                18,5                  22              0,8/0,2/1,0         CH3/IP00       160x431x240            30
NXP00455A0N1SWSA1A2                45             41               30                  22                   30              1,0/0,3/1,3         CH3/IP00       160x431x240            30
NXP00615A0N1SWSA1A2                61             55               41                  30                   37              1,3/0,3/1,5         CH3/IP00       160x431x240            30
NXP00725A0N0SWSA1A2                72             65               48                  37                   45              1,2/0,3/1,5         CH4/IP00       190x493x258            35
NXP00875A0N0SWSA1A2                87             79               58                  45                   55              1,5/0,3/1,8         CH4/IP00       190x493x258            35
NXP01055A0N0SWSA1A2               105            95               70                  55                   75              1,8/0,3/2,1         CH4/IP00       190x493x258            35
NXP01405A0N0SWSA1A2               140           127              93                  75                   90              2,3/0,3/2,6         CH4/IP00       190x493x258            35
NXP01685A0N0SWSA1A2               168           153             112                 90                  110             4,0/0,4/4,4         CH5/IP00       246x553x264            40
NXP02055A0N0SWSA1A2               205           186             137                110                 132             5,0/0,5/5,5         CH5/IP00       246x553x264            40
NXP02615A0N0SWSA1A2               261           237             174                132                 160             6,0/0,5/6,5         CH5/IP00       246x553x264            40
NXP03005A0N0SWFA1A2               300           273             200                160                 200             7,0/0,6/7,6        CH61/IP00      246x658x374            55
NXP03855A0N0SWFA1A2               385           350             257                200                 250             9,0/0,7/9,7        CH61/IP00      246x658x374            55
NXP04605A0N0SWFA1A2               460           418             307                250                 315             6,5/0,5/7,0        CH72/IP00     246x1076x372         90
NXP05205A0N0SWFA1A2               520           473             347                250                 355             7,5/0,6/8,1        CH72/IP00     246x1076x372         90
NXP05905A0N0SWFA1A2               590           536             393                315                 400             9,0/0,7/9,7        CH72/IP00     246x1076x372         90
NXP06505A0N0SWFA1A2               650           591             433                355                 450           10,0/0,7/10,7     CH72/IP00     246x1076x372         90
NXP07305A0N0SWFA1A2               730           664             487                400                 500           12,0/0,8/12,8     CH72/IP00     246x1076x372         90
NXP08205A0N0SWFA1A2               820           745             547                450                 560           12,5/0,8/13,3     CH63/IP00      492x658x380           120
NXP09205A0N0SWFA1A2               920           836             613                500                 600           14,4/0,9/15,3     CH63/IP00      492x658x380           120
NXP10305A0N0SWFA1A2               1030           936             687                560                 700           16,5/1,0/17,5     CH63/IP00      492x658x380           120
NXP11505A0N0SWFA1A2               1150          1045            767                630                 750           18,5/1,0/18,8     CH63/IP00      492x658x380           120
NXP13705A0N0SWFA1A2               1370          1245            913                700                 900           19,0/1,2/20,2     CH74/IP00     746x1124x370        280
NXP16405A0N0SWFA1A2               1640          1491           1093               900                1100          24,0/1,4/25,4     CH74/IP00     746x1124x370        280
NXP20605A0N0SWFA1A2               2060          1873           1373              1100               1400          32,5/1,8/34,3     CH74/IP00     746x1124x370        280
NXP23005A0N0SWFA1A2               2300          2091           1533              1200               1500          36,3/2,0/38,3     CH74/IP00     746x1124x370        280
Thermal Rated Rated Optimum Optimum
Ith contin. IL contin. IH motor at Ith motor at Ith
[A] [A] [A] [465VDC] [kW] [800VDC] [kW]
NXP00165A0T1IWSA1A2                 16             15              11                  8                    11             0,4/10,2/0,6        CH3/IP00       160x431x244            30
NXP00225A0T1IWSA1A2                 22             20              15                 11                   15              0,5/0,2/0,7         CH3/IP00       160x431x244            30
NXP00315A0T1IWSA1A2                 31             28              21                 15                 18,5            0,7/0,2/0,9         CH3/IP00       160x431x244            30
NXP00385A0T1IWSA1A2                 38             35              25                18,5                 22              0,8/0,2/1,0         CH3/IP00       160x431x244            30
NXP00455A0T1IWSA1A2                 45             41              30                 22                   30              1,0/0,3/1,3         CH3/IP00       160x431x244            30
NXP00615A0T1IWSA1A2                 61             55              41                 30                   37              1,3/0,3/1,5         CH3/IP00       160x431x244            30
NXP00725A0T0IWSA1A2                 72             65              48                 37                   45              1,2/0,3/1,5         CH4/IP00       208x493x258            35
NXP00875A0T0IWSA1A2                 87             79              58                 45                   55              1,5/0,3/1,8         CH4/IP00       208x493x258            35
NXP01055A0T0IWSA1A2                105            95              70                 55                   75              1,8/0,3/2,1         CH4/IP00       208x493x258            35
NXP01405A0T0IWSA1A2                140           127              93                 75                   90              2,3/0,3/2,6         CH4/IP00       208x493x258            35
NXP01685A0T0IWSA1A2                168           153             112                 90                  110             2,5/0,3/2,8         CH5/IP00       246x553x264            40
NXP02055A0T0IWSA1A2                205           186             137                110                 132             3,0/0,4/3,4         CH5/IP00       246x553x264            40
NXP02615A0T0IWSA1A2                261           237             174                132                 160             4,0/0,4/4,4         CH5/IP00       246x553x264            40
NXP03005A0T0IWFA1A2                300           273             200                160                 200             4,5/0,4/4,9        CH61/IP00      246x553x232            55
NXP03855A0T0IWFA1A2                385           350             257                200                 250             5,5/0,5/6,0        CH61/IP00      246x658x374            55
NXP04605A0T0IWFA1A2                460           418             307                250                 315             5,5/0,5/6,0        CH62/IP00      246x658x374            55
NXP05205A0T0SWSA1A2               520           473             347                250                 355             6,5/0,5/7,0        CH62/IP00      246x658x374            55
NXP05905A0T0IWFA1A2                590           536             393                315                 400             7,5/0,6/8,1        CH62/IP00      246x658x374            55
NXP06505A0T0IWFA1A2                650           591             433                355                 400             8,5/0,6/9,1        CH62/IP00      246x658x374            55
NXP07305A0T0IWFA1A2                730           664             487                400                 450           10,0/0,7/10,7      CH62/IP00      246x658x374            55
NXP08205A0T0IWFA1A2                820           745             547                450                 560           10,0/0,7/10,7      CH63/IP00      492x658x380           120
NXP09205A0T0IWFA1A2                920           836             613                500                 630           12,4/0,8/12,4      CH63/IP00      492x658x380           120
NXP10305A0T0IWFA1A2                1030          936             687                560                 700           13,5/0,9/14,4      CH63/IP00      492x658x380           120
NXP11505A0T0IWFA1A2                1150         1045            767                630                 800           16,0/1,0/17,0      CH63/IP00      492x658x380           120
NXP13705A0T0IWFA1A2                1370         1245            913                700                 900           15,5/1,0/16,5      CH64/IP00      738x658x374           180
NXP16405A0T0IWFA1A2                1640         1491           1093               900                1100          19,5/1,2/20,7      CH64/IP00      738x658x374           180
NXP20605A0T0IWFA1A2                2060         1873           1373              1100               1400          26,5/1,5/28,0      CH64/IP00      738x658x374           180
NXP23005A0T0IWFA1A2                2300         2091           1533              1250               1500          34,0/1,8/34,3      CH64/IP00      738x658x374           180
Thermal Rated Rated Optimum Optimum
Ith contin. IL contin. IH motor at Ith motor at Ith
[A] [A] [A] [525VAC] [kW] [690VAC] [kW]
NXP01706A0T0SWFA1A2                170           155             113                110                 160             7,5/0,4/7,9        CH61/IP00      246X658X374            55
NXP02086A0T0SWFA1A2                208           189             139                132                 200             9,0/0,5/9,5        CH61/IP00      246X658X374            55
NXP02616A0T0SWFA1A2                261           237             174                160                 250             6,5/0,3/6,8        CH61/IP00     246X1076X372           90
NXP03256A0T0SWFA1A2                325           295             217                200                 250             7,5/0,4/7,9        CH72/IP00     246X1076X373           90
NXP03856A0T0SWFA1A2                385           350             257                250                 355             9,0/0,5/9,5        CH72/IP00     246X1076X374           90
NXP04166A0T0SWFA1A2                416           378             277                250                 355             9,4/0,5/9,9        CH72/IP00     246X1076X375           90
NXP04606A0T0SWFA1A2                460           418             307                315                 400           10,0/0,5/10,5      CH72/IP00     246X1076X376           90
NXP05026A0T0SWFA1A2                502           456             335                355                 450           12,0/0,6/12,6      CH72/IP00     246X1076X377           90
NXP05906A0T0SWFA1A2                590           536             393                400                 560           13,0/0,7/13,7      CH63/IP00      492X658X380           120
NXP06506A0T0SWFA1A2                650           591             433                450                 600           16,0/0,8/16,8      CH63/IP00      492X658X380           120
NXP07506A0T0SWFA1A2                750           682             500                500                 700           18,0/0,9/18,9      CH63/IP00      492X658X380           120
NXP08206A0T0SWFA1A2                820           745             547                600                 750           19,0/1,0/20,0      CH74/IP00     746X1124X370          280
NXP09206A0T0SWFA1A2                920           836             613                650                 800           20,0/1,0/21,4      CH74/IP00     746X1124X370          280
NXP10306A0T0SWFA1A2               1030           936             687                750                 950           22,0/1,1/23,1      CH74/IP00     746X1124X370          280
NXP11806A0T0SWFA1A2               1180          1073            787                800                1100          25,0/1,3/26,3      CH74/IP00     746X1124X370          280
NXP13006A0T0SWFA1A2               1300          1182            867                950                1200          31,0/1,6/32,6      CH74/IP00     746X1124X370          280
NXP15006A0T0SWFA1A2               1500          1364           1000              1050               1400          38,0/1,9/39,9      CH74/IP00     746X1124X370          280
NXP01706A0T0IWFA1A2                 170           155             113                124                 214             4,5/0,2/4,7        CH61/IP00      246X658X374            55
NXP02086A0T0IWFA1A2                 208           189             139                152                 261             5,5/0,3/5,8        CH61/IP00      246X658X374            55
NXP02616A0T0IWFA1A2                 261           237             174                193                 332             5,5/0,3/5,8        CH62/IP00      246X658X374            55
NXP03256A0T0IWFA1A2                 325           295             217                240                 413             6,5/0,3/6,8        CH62/IP00      246X658X374            55
NXP03856A0T0IWFA1A2                 385           350             257                285                 489             7,5/0,4/7,9        CH62/IP00      246X658X374            55
NXP04166A0T0IWFA1A2                 416           378             277                311                 518             8,1/0,4/8,4        CH62/IP00      246X658X374            55
NXP04606A0T0IWFA1A2                 460           418             307                340                 584             8,5/0,4/8,9        CH62/IP00      246X658X374            55
NXP05026A0T0IWFA1A2                 502           456             335                375                 645           10,0/0,5/10,5      CH62/IP00      246X658X374            55
NXP05906A0T0IWFA1A2                 590           536             393                441                 758           10,0/0,5/10,5      CH63/IP00      492X658X380           120
NXP06506A0T0IWFA1A2                 650           591             433                486                 835           13,5/0,7/14,2      CH63/IP00      492X658X380           120
NXP07506A0T0IWFA1A2                 750           682             500                560                 963           16,0/0,8/16,8      CH63/IP00      492X658X380           120
NXP08206A0T0IWFA1A2                 820           745             547                613                1053          16,0/0,8/16,8      CH64/IP00      738X658X374           180
NXP09206A0T0IWFA1A2                 920           836             613                688                1147          17,8/1,0/18,4      CH64/IP00      738X658X374           180
NXP10306A0T0IWFA1A2                1030           936             687                770                1323          19,0/1,0/20,0      CH64/IP00      738X658X374           180
NXP11806A0T0IWFA1A2                1180          1073            787                882                1515          21,0/1,1/22,1      CH64/IP00      738X658X374           180
NXP13006A0T0IWFA1A2                1300          1182            867                982                1688          27,0/1,4/28,4      CH64/IP00      738X658X374           180
NXP15006A0T0IWFA1A2                1500          1364           1000              1133               1948          32,0/1,6/33,6      CH64/IP00      738X658X374           180
CON-1                                         CH61, CH62, CH72                        Spin nut connection kit                                                                      2pc.
CON-2                                         CH63                                            Spin nut connection kit                                                                      4pc.
CON-3                                         CH64, CH74                                  Spin nut connection kit                                                                      6pc.
CON-4                                         CH61, CH62, CH72                        TEMA hose kit                                                                                    2pc.
CON-5                                         CH63                                            TEMA hose kit                                                                                    4pc.
CON-6                                         CH64, CH74                                  TEMA hose kit                                                                                    6pc.
PP60017 CH3-CH7 Fiber optic cable set 0,7m
PP60010 CH3-CH7 Fiber optic cable set 1,5m
PP60016 CH3-CH7 Fiber optic cable set 3,5m
PP31001 CH3-CH4 Cable set CU-PU 1,15m
PP51015 CH5 Cable set CU-PU 1,15m
FW00150                                                                                         1,5 m cooling hose
FW00151                                                                                         1,5 m cooling hose
FW00152                                                                                         1,0 m cooling hose
FW00157                                                                                         1,5 m cooling hose
FW00158                                                                                         1,5 m cooling hose + conduit *
FW00205                                                                                         Cooling hose adapter al 160 x d 32 mm                                   2 pcs per 1 cooling element
ORDER TYPE CODE            SUITABILITY DESCRIPTION NOTE
HXL-V-040-N-P Heat exchanger installed into IP21-cabinet IP21
HXL-V-120-N-P Heat exchanger installed into IP21-cabinet IP21
HXM-V-120-N-P Heat exchanger installed into IP21-cabinet IP21
Vacon Liquid Cooled OPTIONS Water chillers 400-500 VAC    
ORDER TYPE CODE            SUITABILITY
kW        bar           l/min
DESCRIPTION NOTE
P@35C       P@45C             p                   q    
UC-0030SP                                       3,8            3,3               3                  20           Water chiller                                                              IP44
UC-0080SP                                      13,7          11,2             3,5                 40           Water chiller                                                              IP54
UC-0140SP                                      22,1          18,3             3,5                 80           Water chiller                                                              IP54
UC-0240SP                                      41,8          34,2              3                  120          Water chiller                                                              IP54
UC-0400SP                                      48,6             -               3,5                120          Water chiller                                                              IP54
UC-0800SP                                      97,2             -               3,5                240          Water chiller                                                              IP54
UC-0500SP/E                                      -              43              3,5                120          Water chiller                                                              IP54
UC-1000SP/E                                      -              86              3,5                240          Water chiller                                                              IP54